Adjust Cut-off Timer:
1. Do not alter factory setting, unless necessary.
2. A small copper screw found on the back of the tool handle (above the reset
button) adjusts the cut-off timing. (Fig. 8)
3. Using a small, standard screwdriver, turn the screw clockwise to increase
the cut-off delay, and counter-clockwise to decrease the cut-off delay.
Adjusting cut-off delay timing too short will result in premature cut-off, and a
loose clamp. The moment cut-off is actuated, the pressure gauge shows the
correct tension setting