Disassembly & Inspection:
1)
Remove the two Compression Springs.
2)
Remove Tension Gripper and Tension Block pin from the Tension Block.
3)
Tension Gripper — Look for worn spots or other damage.
4)
Tension Block — Look for damaged edge on insert or other damage. See the “Trouble
Shooting Guide: Unable to Achieve Tension” page 24 for details.
Reassembly:
1)
Thoroughly clean out any accumulated debris from inside the Tension Block
2)
Lubricate the surfaces shown with red arrows
3)
Install the Tension Gripper and Tension Block Pin in the Tension Block.
4)
Reinstall the Compression Springs
Maintenance: Tension Block Inspection & Replacement
Note: Ensure no lubrication is present in
the center of Tension Gripper (indicated
by the circled area)
Clean out any
accumulated debris
from the slot in the
Tension Block
Lightly lubricate all outside surfaces
of tension block and surfaces
indicated with red arrows
.
Tension Block Pin
Compression Springs
Tension Block
Tension Gripper
Insert