37
7. Operation
Operation
Test Mode
Troubleshooting
Test Mode
Troubleshooting
(2) SWITCH TEST
This screen is used to test each switch and control.
In the I/O TEST screen, select SWITCH TEST and press the Enter switch. The SWITCH
TEST screen appears.
Flip the Select switch up or down to select the item to be tested.
SWITCH TEST screen
SWITCH TEST
[ON: RED ]
COIN INPUT1
0
COIN INPUT2
0
SERVICE OFF
TEST ON
UP SELECT
OFF
DOWN SELECT
OFF
ENTER OFF
MACHINE GUN
OFF
MISSILE OFF
SERVICE PANEL
OFF
THROTTLE LEVER
Y:0500
CONTROL LEVER
X:0500
Y:0500
UP SELECT ENTER:EXIT
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
(m)
Item
Description
(a)
COIN INPUT1
Counts up each time there is coin input (for coin). When the count exceeds “999” it
returns to “0”.
(b)
COIN INPUT2
Counts up each time there is coin input (for the Bill Validator). When the count exceeds
“999” it returns to “0”.
(c)
SERVICE
Indicates ON while the Service switch is pressed.
(d)
TEST
Indicates ON while the Test switch is set to ON. (This screen is accessed in Test
mode, so this is naturally ON.)
(e)
UP SELECT
Indicates UP while the Select switch is flipped up.
(f)
DOWN SELECT
Indicates DOWN while the Select switch is flipped down.
(g)
ENTER
Indicates ON while the Enter switch is pressed.
(h)
MACHINE GUN
Indicates ON while the trigger switch on the control lever is squeezed.
(i)
MISSILE
Indicates ON while the button switch on the control lever is pressed.
(j)
SERVICE PANEL
Indicates ON while the service panel is open.
(k)
THROTTLE LEVER
The numerical values change when the throttle lever is tilted forward and back.
If “UP OK!” and “DOWN OK!” are displayed, the lever is operating normally.
(l)
CONTROL LEVER X
The numerical values change when the control lever is tilted to the right and left.
If “LEFT OK!” and “RIGHT OK!” are displayed, the lever is operating normally.
(m)
CONTROL LEVER Y
The numerical values change when the control lever is tilted forward and back.
If “UP OK!” and “DOWN OK!” are displayed, the lever is operating normally.
Press the Enter switch to enter the selected item.
Hold the Select switch flipped up and press the Enter switch to return to the I/O TEST screen.