6.2.
Specifications
GENERAL
TYPE:
Cable Reinforced Vehicle Arresting Barrier
CRASH RATING:
ASTM F2656-15, M30-P1
15,000 lbs. @ 30 mph (6,803 kg @ 48 km/h)
DRIVE SYSTEM:
Electromechanical, Hydraulic or Manual
INSTALLATION
EXCAVATION:
Minimum 5 ft. x 5 ft. x 4 ft. (1.5 x 1.5 x 1.2 m)
excavation per stanchion
SOIL COMPACTION:
1,600 PSF (76.6 kN/m
2
) Minimum
CONCRETE:
Concrete must develop a minimum compressive
strength of 4000 PSI (27.6 MN/m
2
)
Concrete must conform to American Concrete
Institute (ACI) standards.
Cement shall be per ASTM C150.
Maximum aggregate size is 1 in. (25 mm)
Approximate 3.7 cubic yards (2.8 cubic meters) per
stanchion
REBAR:
Rebar shall be #4 deformed billet steel per ASTM
A615, Grade 60.
Cages shall be tied together using #4 ties.
DESIGN
CLEAR VEHICLE OPENING:
Ranges from 12 to 30 ft. (144 – 360 in. / 3.7 – 9.1 m)
CYCLE TIME:
ELECTRIC
STD. Operation 7-15 sec; Field Configurable
HYDRAULIC
STD. Operation 7-15 sec; Field Configurable
DUTY CYCLE:
Continuous
OPERATING :
TEMPS
-20 – 140º F (-29 - 60º C)
ANGLE
90º ± 5º
MATERIALS:
STANCHION
Hot dip galvanized Steel
ARM
6061 aluminum extrusion
ELECTRICAL
REQUIREMENTS:
773Ex
115-240 VAC 1Ø; 208-480VAC 3Ø
773Hx
115-240 VAC 1Ø; 208-480VAC 3Ø
773MD
N/A
DIMENSIONS:
Project Specific – reference Submittal package
OIL:
773Hx
EnviroLogic® 132 or equivalent
FINISH:
Project specific colored Macropoxy® 646, finished with
Acrolon™ 218 acrylic polyurethane