Zlinx™ Xtreme Modem (one of the following models):
o
ZXT24-RM
o
ZXT9-RM
This Quick Start Guide
CD with Zlinx™ Manager Software and manual
Antenna
IP67 Cable Gland
IP67 Membrane Cable Gland
Watertight threaded conduit hub
Mounting ears and hardware
Additional items required but not included:
o
10 – 30 VDC Power Supply
o
USB Cable
I
I
n
n
s
s
t
t
a
a
l
l
l
l
Z
Z
l
l
i
i
n
n
x
x
™
™
M
M
a
a
n
n
a
a
g
g
e
e
r
r
S
S
o
o
f
f
t
t
w
w
a
a
r
r
e
e
Insert the CD into your CD ROM Drive. The Zlinx™
Manager Install Wizard should start. Follow the on-screen
instructions to install the software.
If auto run is disabled, locate the ZlinxMgr.exe file on the
CD-ROM drive and double click to launch it. The Install
Wizard should start. Follow the on-screen instructions.
I
I
n
n
s
s
t
t
a
a
l
l
l
l
U
U
S
S
B
B
D
D
r
r
i
i
v
v
e
e
r
r
s
s
Connect the device to the USB port on your PC.
The “Found New Hardware Wizard” will guide you through
the installation process.
When prompted to connect to Windows Updates to search for
drivers, select “No, not at this time” and follow the instructions
for installing from the CD or the location on the hard drive.
Choose the drivers manually from the CD or the location
where Zlinx™ Manager Software is installed.
When the driver is installed a new COM port labeled
“Xtreme” will show up in Windows Device Manager.
P
P
o
o
w
w
e
e
r
r
C
C
o
o
n
n
n
n
e
e
c
c
t
t
i
i
o
o
n
n
,
,
T
T
B
B
,
,
&
&
A
A
n
n
t
t
e
e
n
n
n
n
a
a
Connect the power supply to the PWR IN +/-
terminals on the terminal block.
Connect the supplied antenna to the RPSMA
connector.
Operating Voltage – 10 to 30 VDC
Maximum Surrounding Ambient Air Temperature - 74°C
Wiring Terminals – Use Copper Wire Only, one
conductor per terminal
Wire Range 30 – 12 AWG
Temperature rating of field installed conductors - 105°C
minimum, sized for 60°C ampacity.
S
S
t
t
a
a
r
r
t
t
Z
Z
l
l
i
i
n
n
x
x
™
™
M
M
a
a
n
n
a
a
g
g
e
e
r
r
S
S
o
o
f
f
t
t
w
w
a
a
r
r
e
e
Start the Zlinx™ Manager Software.
Click on the Radio Modem link.
Click the Radio Modem Configuration link.
o
Select correct COM port and configure it for 9600
baud, Data Bits: 8, Parity: None, Stop Bit: 1.
Figure 3. Communication Parameters Screen
Click the Connect button.
If the modem is not found, the Auto Search button can be
used to locate the modem. The auto search will use a
sequence of COM Ports and settings until the response
is received. If there is still no response, double check the
power supply and USB cable. Also, make sure that no
other devices are attached wired or wirelessly.
Figure 4. Radio Modem Not Found Screen
When the software locates the Radio Modem and you
click the OK button, the Basic Modem Settings screen
will be displayed.
Quick Start Guide
Zlinx™ Xtreme Modem
ZXTxx-RM
3
4
1
2
5