background image

p/n 8593R0-ZXTx-RM-2310qsg 

 

Corporate Headquarters:

  +1 815 433 5100  

www.bb-elec.com

 

European Headquarters:

  +353 91 792444  

www.bb-europe.com

 

 
 

 

 
 

C

C

h

h

e

e

c

c

k

k

 

 

f

f

o

o

r

r

 

 

A

A

l

l

l

l

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

d

d

 

 

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

 

 

‰

 

Zlinx™ Xtreme Modem (one of the following models): 

o

 

ZXT24-RM 

o

 

ZXT9-RM 

‰

 

This Quick Start Guide 

‰

 

CD with Zlinx™ Manager Software and manual 

‰

 

Antenna 

‰

 

IP67 Cable Gland 

‰

 

IP67 Membrane Cable Gland 

‰

 

Watertight threaded conduit hub 

‰

 

Mounting ears and hardware 

‰

 

Additional items required but not included: 

o

 

10 – 30 VDC Power Supply  

o

 

USB Cable 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

Z

Z

l

l

i

i

n

n

x

x

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

 

 

‰

 

Insert the CD into your CD ROM Drive.  The Zlinx™ 

Manager Install Wizard should start. Follow the on-screen 
instructions to install the software. 

‰

 

If auto run is disabled, locate the ZlinxMgr.exe file on the 

CD-ROM drive and double click to launch it.  The Install 
Wizard should start. Follow the on-screen instructions. 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

U

U

S

S

B

B

 

 

D

D

r

r

i

i

v

v

e

e

r

r

s

s

 

 

‰

 

Connect the device to the USB port on your PC. 

‰

 

The “Found New Hardware Wizard” will guide you through 

the installation process. 

‰

 

When prompted to connect to Windows Updates to search for 

drivers, select “No, not at this time” and follow the instructions 
for installing from the CD or the location on the hard drive. 

‰

 

Choose the drivers manually from the CD or the location 
where Zlinx™ Manager Software is installed. 

‰

 

When the driver is installed a new COM port labeled 

“Xtreme” will show up in Windows Device Manager. 

 
 

P

P

o

o

w

w

e

e

r

r

 

 

C

C

o

o

n

n

n

n

e

e

c

c

t

t

i

i

o

o

n

n

,

,

 

 

T

T

B

B

,

,

 

 

&

&

 

 

A

A

n

n

t

t

e

e

n

n

n

n

a

a

 

 

‰

 

Connect the power supply to the PWR IN +/- 
terminals on the terminal block. 

‰

 

Connect the supplied antenna to the RPSMA 
connector. 

 

Operating Voltage – 10 to 30 VDC 
Maximum Surrounding Ambient Air Temperature - 74°C 
Wiring Terminals – Use Copper Wire Only, one 
conductor per terminal  
Wire Range 30 – 12 AWG 
Temperature rating of field installed conductors - 105°C 
minimum, sized for 60°C ampacity.
 

 
 
 

S

S

t

t

a

a

r

r

t

t

 

 

Z

Z

l

l

i

i

n

n

x

x

 

 

M

M

a

a

n

n

a

a

g

g

e

e

r

r

 

 

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

 

 

‰

 

Start the Zlinx™ Manager Software. 

‰

 

Click on the Radio Modem link. 

 

 

‰

 

Click the Radio Modem Configuration link.  

o

 

Select correct COM port and configure it for 9600 
baud, Data Bits: 8, Parity: None, Stop Bit: 1. 

 

Figure 3. Communication Parameters Screen 

‰

 

Click the Connect button. 

‰

 

If the modem is not found, the Auto Search button can be 

used to locate the modem. The auto search will use a 
sequence of COM Ports and settings until the response 
is received. If there is still no response, double check the 
power supply and USB cable. Also, make sure that no 
other devices are attached wired or wirelessly. 

 

Figure 4. Radio Modem Not Found Screen 

 

‰

 

When the software locates the Radio Modem and you 

click the OK button, the Basic Modem Settings screen 
will be displayed. 

Quick Start Guide 

Zlinx™ Xtreme Modem 

ZXTxx-RM 

3

 

4

1

 

2

 

5

Reviews: