MY (Source Address)
Command
<Networking & Security>
Set/Read the source address of
the module.
NB (Parity) Command
<Serial Interfacing>
Select/Read parity settings
for UART communications.
PC (Power-up Mode)
Command
<Command Mode Options>
PC Command allows the
module to power-up directly
into AT Command Mode from
reset or power-on. If PC
Command is enabled with SM
Parameter set to 1, DI3 (pin 2)
can be used to enter the
module into AT Command
Mode. When the DI3 pin is
deasserted (low), the module
will wake-up in AT Command
Mode. This behavior allows module DTR emulation.
AT Command: ATMY
Binary Command: 0x2A (42 decimal)
Parameter Range:
0
– 0xFFFF
Default Parameter Value: 0xFFFF (Disabled
–
the DT (Destination Address) parameter serves
as both source and destination address.)
Number of bytes returned: 2
Related Commands: DT (Destination Address),
HP (Hopping Channel), ID (Modem VID), MK
(Address Mask), AM (Auto-set MY)
Minimum Firmware Version Required: 4.30
AT Command: ATNB
Binary Command: 0x23 (35 decimal)
Parameter Range: 0
– 5
Parameter
Configuration
0
8-bit (no parity or 7-bit (any
parity)
1
8-bit even
2
8-bit odd
3
8-bit mark
4
8-bit space
5
9-bit
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.30
(previous versions did not support the 9
th
bit.
AT Command: ATPC
Binary Command: 0x1E (30 decimal)
Parameter Range: 0
– 1
Parameter
Configuration
0
Power-up to Idle Mode
1
Power-up to AT Command
Mode
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.22