1TT –TIMER + TERMOREGOLATORE - Reference Manual  - Pag. 3 di 7 

 
 
 

Manual modes (pulse generator) 

 
The instrument has two 

manual

 modes that exclude the control algorithms and run the control elements at constant 

power: 

 

Manual mode always on (also with temperature probe); 

 

Manual mode only when there is an error with the temperature probe. 

 

Select manual mode (always on) by selecting the parameter 

MAN

 = 

(the 

MPE

 parameter is ignored). 

To select manual mode only when there is an error with the temperature probe by selecting the parameter 

MAN = 0

 

and 

MPE = 1

 
In both cases the percentage of activation control output is set via the OUT parameter (percentage of the cycle time 
normally used).  
Table (summary): 
 

 

MAN 

MPE 

Manual mode always on 

 

Manual mode in case of error of probe 

 

 
 

Versions with front display

 

 

 

 