EIR-EXTEND-C                    

Ethernet Coaxial Extender  

 
 
 
 

   
 
 

 

 
 
 
 
 
 
 

    
 
    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Front Panel LED’s 

(Ethernet and Line Connections)

 

Port 

LEDs 

Status 

Description 

Ethernet    

(RJ-45) 

Power1 
Power2 
Power3 

Steady 

Power on                                     

Off 

Power off 

Link/ACT 

Steady 

Valid Ethernet 

connection established                          

Flashing 

Transmitting or 

receiving Ethernet 

data (ACT stands for 

ACTIVITY) 

Off 

No valid Ethernet 

connection nor 

transmitting/receiving 

Ethernet data 

FDX 

Steady 

Ethernet connection in 

full duplex mode                                       

(FDX stands for FULL-

DUPLEX) 

Flashing 

Collision occurred 

Off 

Ethernet connection in 

half-duplex mode 

Line      

(BNC) 

Remote 

Steady 

Operating in remote 

mode 

Local 

Steady 

Operating in local 

mode 

Error 

Steady 

Error occurred 

Link 

Steady 

A valid connection 

established between 

local & remote 

1. 

The extender is DIN rail mountable and can be 
located in environments with temperatures ranging 
from -40 to 75°C. Relative humidity should be 
between 5% to 95%, non-condensing. 

 
2. 

Mount the extender on standard DIN rail by hooking 
the top rear of the extender on to the top edge of the 
DIN rail. As the unit is pressed into the DIN rail, the 
spring-loaded bottom tab should snap on, securing 
the bottom. To remove extender from DIN rail, use a 
small flathead screw driver, pull down on the spring 
loaded tab on the bottom of the extender while pulling 
bottom outward. The extender can also be panel 
mounted using the optional panel mount kit 
EIRPMKT. 

 

3. 

Provide  DC  power  to  the  unit  between  12 

– 48 volts. 

While only one power source is required to power up 
the  Ethernet  Extender,  using  two  sources  provides 
redundancy  for  mission  critical  applications.  The 
removable terminal block accepts 14 

– 24 AWG wire.  

Use  copper  conductors  only,  60/75

,  14-24  AWG 

torque value 4.5 lb-in. 

 
4. 

Be sure polarity matches diagram next to the 
terminal block. Terminals labeled Power are 
positive while GND is negative. An optional power 
port labeled Power1 is available with use of 
12VDC AC to DC power adapter (PS12VDC3P). 

 

5. 

Set the DIP switch located on the top of the Ethernet 
Extender to Loc (Local) or Rmt (Remote). Ethernet 
Extenders work in pairs and must have one unit set as 
Loc, the other as Rmt.  

 
6. 

Connect the Ethernet cable to the RJ-45 port on the 
front of Ethernet Extender. 

 

7. 

Connect the coaxial cable to the BNC port on the front 
of the Ethernet Extender. Opposite end connects with 
paired Ethernet Extender located elsewhere. Coax 
cable must be terminated with male BNC or F 
connectors. BNC to F-Type adaptor required for F 
style connector (included).   

 

 

 

o

 

Ethernet Coaxial Extender 

o

 

This Quick Start Guide 

o

 

BNC to F-Type Adaptor 

 
Note: Extender requires 12 

– 48 VDC, 6.8 watts, power 

supply (not included). 

The LED indicators give you instant feedback on status of 
the Ethernet Extender. Both port speeds are auto sensed. 

 

The  EIR-EXTEND-C  provides  one  Ethernet  port  over 
existing coaxial cable.  

 