background image

-4-

AIR SUPPLY AND CONNECTION

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as
tool may explode, possibly causing injury or death.

Do  not  use  supply  sources  which  can  potentially  exceed  200  P.S.I.G. as  tool  may
burst, possibly causing injury.

The connector on the tool must not hold pressure when air supply is disconnected.

If a

wrong fitting is used, the tool can remain charged with air after disconnecting and thus will
be able to drive a fastener even after the air line is disconnected possibly causing injury.

Do not pull trigger or depress contact arm while connected to the air supply as the tool may
cycle, possibly causing injury.

Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool;
3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work area,
as accidental actuation may occur, possibly causing injury.

LOADING TOOL

When loading tool: 1.) Never place a hand or any other part of the body in fastener
discharge area of tool; 2.) Never point tool at anyone; 3.) Do not pull the trigger or depress
the trip as accidental actuation may occur, possibly causing injury.

OPERATION

Always handle the tool with care: 1.) Never engage in horseplay; 2.) Never pull the trigger
unless nose is directed toward the work; 3.) Keep others a safe distance from the tool while
tool is in operation as accidental actuation may occur, possibly causing injury.

The operator must not hold the trigger pulled on contact arm tools except during fastening
operation as serious injury could result if the trip accidentally contacted someone or
something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool. A contact arm tool may
bounce from the recoil of driving a fastener and an unwanted second fastener may be
driven possibly causing injury.

Check operation of the contact arm mechanism frequently. Do not use the tool if the arm is
not working correctly as accidental driving of a fastener may result. Do not interfere with
the proper operation of the contact arm mechanism.

Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as
this may cause deflection of fasteners which could cause injury.

Do not drive fasteners close to the edge of the work piece as the wood may split, allowing
the fastener to be deflected possibly causing injury.

Do not point the tool toward yourself or anyone whether it contains fasteners or not.

Always ensure that the workpiece contact is fully positioned above the workpiece.
Positioning the workpiece contact only partially above the workpiece could cause the
fastener to miss the workpiece completely and result in serious personal injury.

MAINTAINING THE TOOL

When working on tools note the warnings in this manual and use extra care when
evaluating problem tools.

Summary of Contents for FN1564

Page 1: ...S MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR REPRESENTATIVE OR DISTRIBUTOR FN1564 ANGLE FINISH NAILER OPERATION and MAINTENANCE MANUAL ...

Page 2: ...r s employees are not qualified to advise you on the use of these tools Oral representation will not be binding on the Seller The rights under this limited warranty are to the original purchaser and may not be transferred to the subsequent owner This limited warranty is in lieu of all warranties expressed or implied including warranties of merchantability and fitness for a particular purpose Selle...

Page 3: ...ed repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury When servicing a tool use only identical replacement parts Use of unauthorized parts may create a risk of injury Know your pneumatic tool Read operator s manual carefully Learn its applications and limitations as well as the specific potential hazards related to this tool Following this rul...

Page 4: ...istance from the tool while tool is in operation as accidental actuation may occur possibly causing injury The operator must not hold the trigger pulled on contact arm tools except during fastening operation as serious injury could result if the trip accidentally contacted someone or something causing the tool to cycle Keep hands and body away from the discharge area of the tool A contact arm tool...

Page 5: ...rect operating pressure for the tool FILTER Dirt and water in the air supply are major causes of wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instru...

Page 6: ...NG The light weight magnesium housing helps reduce work fatigue TOOL FREE DRIVE DEPTH ADJUST The tool free depth adjust lets the operator select precise driving depth of the fastener TOOL FREE JAM RELEASE A tool free jam release is provided for ease in clearing infrequent jams NO MAR TIPS The no mar tips prevent marring and denting when using the tool on softer woods REAR LOADING MAGAZINE The rear...

Page 7: ...control of the fastener drive depth from flush with the work surface to shallow or deep countersink First set the air pressure for consistent drive in the specific work Then use the depth adjustment to give the desired depth of drive TO ADJUST FASTENER CONTROL ADJUSTMENT 1 Disconnect the tool from the air supply 2 Turn the depth selector left or right to change the driving depth 3 Reconnect the to...

Page 8: ...ever point the tool at anyone else Never engage in horseplay Never pull the trigger unless nose is directed at the work Always handle the tool with care Do not pull the trigger or depress the trip mechanism while loading the tool 1 Insert nails into track of magazine 2 Pull pusher all the way back and then allow it to push nails forward to driving position ...

Page 9: ...T To operate the tool in this manner first position the contact trip on the work surface WITHOUT PULLING THE TRIGGER Depress the contact trip until the nose touches the work surface and then pull the trigger to drive a fastener Do not press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fastener Remove your finger from th...

Page 10: ...MUST NOT CYCLE Release the trigger The trigger must return to the trigger stop on the frame C Pull the trigger and press the contact trip against the work surface THE TOOL MUST NOT CYCLE D With finger off the trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATIO...

Page 11: ...PROCEDURE FOR SEALS When repairing a tool make sure the internal parts are clean and lubricated Use a small amount of oil on all moving surfaces and pivots After reassembly add a few drops of oil through the air line fitting before testing AIR SUPPLY PRESSURE AND VOLUME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersized fittings a...

Page 12: ...te Air pressure too low Check air supply equipment Skipping fasteners intermittent feed Worn bumper Replace bumper Tar dirt in driver channel Disassemble and clean nose and driver Air restriction inadequate air flow through quick disconnect socket and plug Replace quick disconnect fittings Worn piston O ring Replace O ring check driver Tool dry lacks lubrication Use Lubricant Low air pressure Chec...