background image

-10-

MAINTAINING THE PNEUMATIC TOOL

When working on air tools, note the warnings in this manual and use extra care evaluating
problem tools.

CAUTION: Pusher spring (constant force spring). Caution must be used when working
with the spring assembly. The spring is wrapped around, but not attached to, a roller. If
the spring is extended beyond its length, the end will come off the roller and the spring
will roll up with a snap, with a chance of pinching your hand. Also the edges of the spring
are very thin and could cut. Care must also be taken to insure no permanent kinks are
put in the spring as this will reduce the springs force.

REPLACEMENT PARTS:

B&C Eagle replacement parts are recommended. Do not use modified parts or parts which will not give
equivalent performance to the original equipment.

ASSEMBLY PROCEDURE FOR SEALS:

When repairing a tool, make sure the internal parts are clean and lubricated. Use a small amount of oil on all
moving surfaces and pivots. After reassembly add a few drops of oil through the air line fitting before testing.

AIR SUPPLY-PRESSURE AND VOLUME:

Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because of
undersized fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will prevent
the tool from receiving an adequate volume of air, even though the pressure reading is high. The results will be
slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these symptoms, trace
the air supply from the tool to the supply source for restrictive connectors, swivel fittings, low points containing
water and anything else that would prevent full volume flow of air to the tool.

CAUTION: If the tool does not work as it should, contact a B&C Eagle service center immediately.

Summary of Contents for MC150

Page 1: ... MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE IF YOU HAVE ANY QUESTIONS CONTACT YOUR REPRESENTATIVE OR DISTRIBUTOR MC150 METAL CONNECTOR NAILER OPERATION and MAINTENANCE MANUAL ...

Page 2: ...ees are not qualified to advise you on the use of these tools Oral representation will not be binding on the Seller The rights under this limited warranty are to the original purchaser and may not be transferred to the subsequent owner This limited warranty is in lieu of all warranties expressed or implied including warranties of merchantability and fitness for a particular purpose Seller shall no...

Page 3: ...ed repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury When servicing a tool use only identical replacement parts Use of unauthorized parts may create a risk of injury Know your pneumatic tool Read operator s manual carefully Learn its applications and limitations as well as the specific potential hazards related to this tool Following this rul...

Page 4: ...istance from the tool while tool is in operation as accidental actuation may occur possibly causing injury The operator must not hold the trigger pulled on contact arm tools except during fastening operation as serious injury could result if the trip accidentally contacted someone or something causing the tool to cycle Keep hands and body away from the discharge area of the tool A contact arm tool...

Page 5: ...rect operating pressure for the tool FILTER Dirt and water in the air supply are major causes of wear in pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instru...

Page 6: ...reference LIGHT WEIGHT MAGNESIUM HOUSING The light weight magnesium housing helps reduce work fatigue DRY FIRE LOCKOUT The drive fire lockout extends driver life and prevents missing nails SEQUENTIAL FIRING The sequential firing mechanism ensure precision nail placement REAR LOADING MAGAZINE The rear loading magazine offers quick reloading of fasteners PRODUCT SPECIFICATIONS TOOL FREE MULTI DIRECT...

Page 7: ...NJURIES Never place a hand or any other part of the body in nail discharge area of tool while the air supply is connected Never point the tool at anyone else Never engage in horseplay Never pull the trigger unless nose is directed at the work Always handle the tool with care Do not pull the trigger or depress the trip mechanism while loading the tool 1 Insert nails into track of magazine 2 Pull pu...

Page 8: ...The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the employer and user must ensure that head protection conforming to ANSI Z89 1 is used BEFORE HANDLING OR OPERATING THIS TOOL I READ AND UNDERSTAND THE WARNINGS CONTAINED IN THIS M...

Page 9: ...gainst the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION Use the B C Eagle pneumatic tool only for the purpose for which it was designed Never use this tool in a manner that could cause a fastener to be directed toward the user or others in the work area Do not use the tool as a hammer Always ca...

Page 10: ...PROCEDURE FOR SEALS When repairing a tool make sure the internal parts are clean and lubricated Use a small amount of oil on all moving surfaces and pivots After reassembly add a few drops of oil through the air line fitting before testing AIR SUPPLY PRESSURE AND VOLUME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersized fittings a...

Page 11: ...te Air pressure too low Check air supply equipment Skipping fasteners intermittent feed Worn bumper Replace bumper Tar dirt in driver channel Disassemble and clean nose and driver Air restriction inadequate air flow through quick disconnect socket and plug Replace quick disconnect fittings Worn piston O ring Replace O ring check driver Tool dry lacks lubrication Use Lubricant Low air pressure Chec...