If the machine is configured to work with two resister groups, the first group of resistors controls
the temperature regulation and the second group of resistors continues operating when the tem-
perature is below the preset temperature, and switches off when the preset temperature is attained.
The second group of resistors is activated again when the temperature falls below the set point.
Refer to Section 6.7 on page 26 for further details.
To show that the heating is activated when the two heating groups are operating, the decimal point
on the temperature display is permanently lit. When a single group is operating, the decimal point
flashes.
6.5.2
Gas Heating
For gas heated models, the machine is equipped with an electronic device that controls the ignition
and functioning of the burner. The microprocessor turns on the gas burner when the ironing
cylinder temperature is lower than the preset temperature.
Call for heat is indicated by the decimal point on the temperature display.
Section 6.6 on page 24 explains what to do in the event that there is no flame.
6.5.3
Progamming the Working Temperature
The temperature setting can be programmed as follows:
•
Press the SET button
The last programmed value will flash on the display:
23