Use the + and - buttons to modify the value. By holding the key down, the numbers will quickly
increase or decrease.
3 seconds after releasing the + or - button the value is stored and the measured temperature is
shown again on the display.
Programmable range: 0...Tmax
◦
C (32...Tmax
◦
F) Resolution: 1
◦
C
The maximum value that the user can set (Tmax) is programmable. Refer to Section 6.7 on page
26 for further details.
Electrcially heated ironers modulate the heating contactor when approaching the working tem-
perature set point. It is normal to hear the heating relay switch engaging repeatedly during this
period.
6.6
Alarm Messages
6.6.1
AL1 - Insufficient Airflow
The alarm is only used when the machine is configured for gas heating.
If the pressure switch on the exhaust opens for 2 seconds, the buzzer is activated for 1 minute and
AL1 appears on the display.
6.6.2
AL4 - Fan Thermal Relay
When the fan thermal relay trips, the buzzer is activated for 1 minute and AL4 appears on the
display: