The sound proof box must also be cleaned and decontaminated (if necessary) – see the next 
section. 

 Certi

fi

 cate of Decontamination  

If the sound proof box is sent back to the manufacturer for repairs (with accessories, if 
applicable), the form "Certi

fi

 cate of Decontamination" must be 

fi

 lled out and a

  xed in a clearly 

visible location on the outside of the packing.
If this form has not been 

fi

 lled out, we reserve the right to refuse receipt of the package in order 

to protect our employees.

The form can be downloaded from our website as a PDF 

fi

 le:

www.bandelin.com/Downloads 

7  

Accessories  

Correct accessories facilitate the application. 

No-obligation telephone consultation:  

 

Website:

  +49 30 768 80-0 

 

 

 

www.bandelin.com

A suitable stand is required for operation of the SONOPULS ultrasonic homogeniser in the 
sound proof box. 

Stand SONOPULS HG 40

for application with or without the sound proof box

Code No.: 3681

-  External dimensions: 310 × 310 × 820 mm (L×W×H)
-  With holder WH 40, insert for UW 50 and non-slip mat
-  Standard sleeves can be mounted on the stand rod (d = 16 mm)
-  Material (base and rod): Stainless steel

Additional accessories:

WH 40 holder 
-  For indirect sonication with the SONOPULS ultrasonic homogeniser 

and stand HG 40 in the sound proof box

Material: POM
Code No.: 3900

Supporting table AT 40 
-  For sample positioning on stand HG 40
Material: POM
Code No.: 3901

Summary of Contents for SONOPULS LS 40

Page 1: ...7 LS 40 Sound proof box 51766 GB 2020 06 Instructions for Use...

Page 2: ...nal version will take precedence BANDELIN accepts no responsibility or liability for damage caused by improper handling or usage contrary to the intended purpose The documentation has been prepared wi...

Page 3: ...y responsibility for the device s safety or functional ability in the event of improper handling or usage contrary to the intended purpose Unauthorised alterations modifications will render both the w...

Page 4: ...1 4 Technical data 8 1 4 1 Electromagnetic compatibility EMC 8 1 5 Warnings and safety instructions 9 2 Preparation 10 2 1 Scope of delivery 10 2 2 Installation assembly 10 2 3 Commissioning 11 3 Ope...

Page 5: ...6 1 electronic GmbH Co KG Heinrichstra e 3 4 12207 Berlin Deutschland info bandelin com 6 Maintenance and repair 14 6 1 Servicing 14 6 2 Troubleshooting 14 6 3 Repairs and service 14 7 Accessories 15...

Page 6: ...pe plate on the rear Product features 1 Body 2 Door with acrylic glass window 3 Handle 4 Seal 5 Perforated plate removable 6 Drip tray removable 7 LED interior lighting 8 Ventilation system 9 Splash g...

Page 7: ...sample fluids are collected in the drip tray For a necessary cleaning the drip tray can be removed The perforated plate above the drip tray enables a stable positioning of the stand or sample vessels...

Page 8: ...type plate Degree of protection IP 2X pursuant to EN 60529 Ambient conditions pursuant to EN 61 010 1 Overvoltage category II Degree of contamination 2 Permissible ambient temperature 5 to 40 C Permis...

Page 9: ...hing should be inserted into the ventilation system and the fan should not be blocked Caution Magnetic field For the closure mechanism both the door and the body of the sound proof box contain neodymi...

Page 10: ...for use Additional accessories as ordered see delivery note 2 2 Installation assembly Caution The sound proof box is too heavy to be set up by a single person The sound proof box should always be unpa...

Page 11: ...tton Place the perforated plate on the bottom of the sound proof box and slide the drip tray below 3 Operation The lighting and ventilation system of the sound proof box are switched on o using the pu...

Page 12: ...damage to the sound proof box 4 2 General use Open the door of the sound proof box completely Place the perforated plate on the bottom of the sound proof box and slide the drip tray below Position the...

Page 13: ...the sample vessels on the perforated plate or the supporting table AT 40 of the stand HG 40 If required use the non slip mat or similar 5 Cleaning and maintenance Cleaning and maintenance should be p...

Page 14: ...fective Fan defective Replacement required send in for repair if necessary Reduced noise protection Door not closed correctly Close door correctly clean magnetic closure Door seal damaged Replace door...

Page 15: ...r website as a PDF file www bandelin com Downloads 7 Accessories Correct accessories facilitate the application No obligation telephone consultation Website 49 30 768 80 0 www bandelin com A suitable...

Page 16: ...ontaminated before disposal Afterwards the device can be disposed of as electronic waste If decontamination cannot be carried out completely or correctly a safety data sheet of the substances used mus...

Reviews: