Warnings and safety precautions
General
• Keep the ultrasonic bath out of the reach of children and also of persons who have not been
instructed in their operation by reference to these instructions.
• We will not offer a guarantee for damages to the ultrasonic bath or oscillating tank, or to the
objects to be treated, as a result of use of inadequate disinfection agents or detergents.
• Keep the surface of the ultrasonic bath and operating elements clean and dry.
• Do not expose the ultrasonic bath to corroding in
fl
uences.
• Move the ultrasonic bath only when it is empty.
• Empty the ultrasonic bath only while turned off.
• Ultrasonic baths adhere to prescribed EMC limit values, such that it can be assumed that the
electromagnetic radiation emanating from the units is harmless to humans. However, a binding
statement for wearers of implants can only be made at the place of work and together with the
implant manufacturer. In case of doubt, information regarding the allowable electromagnetic
exposure level is to be obtained from the implant manufacturer.
Operation
• Observe ambient and set-up conditions, see Section 1.4.
• Only plug in the ultrasonic bath to an outlet with a grounded socket.
• Do not operate the ultrasonic bath without
fl
uids.
• Do not stand or lay any objects on the tank bottom, accessories must be used, see Section 7.
• Do not immerse any parts of the body (e.g., hands, feet) or living beings (animals or plants)
into the tank; in particular, do not immerse them in the bath
fl
uid during ultrasound operation.
Danger: Ultrasound has a cell-destroying effect.
• In the event of continuous activity within a 2 m radius, adequate hearing protection must be
used. Danger: Hearing disturbances during operation when not wearing hearing protection – the
typical ultrasound cavitation noise can be very uncomfortable.
• Do not operate the ultrasonic bath while unattended.
Advice for the medical and laboratory
fi
eld
• The ultrasonic bath is exclusively intended for use by medical skilled personnel.
• It may generate radio interferences or disrupt the operation of devices nearby. It may be
necessary to take remedial measures such as realigning the device or a recon
fi
guration of the
ultrasonic bath or the shield.
• During operation, portable or mobile HF communication systems in the vicinity of the ultrasonic
bath should be turned off – their operation may be disrupted.
Damages
• If damage to the ultrasonic bath is detected, do not connect the ultrasonic bath to the mains.
• In
the event of defects, disconnect the mains plug immediately.
•
Repairs are only to be conducted by authorised skilled personnel or by the manufacturer.
•
Defective parts may only be replaced with original parts.