H3000 Pilot Handbook
106
HB-3001-03
FAULT DIAGNOSIS
Fault 100 – Pilot not Commissioned
Fault Description
The rudder end stops on the Pilot have not been commissioned, or the memory has
been corrupted.
Remedial Action
1)
Has the Pilot ever been successfully commissioned?
Yes
go to step (4)
No
go to step (2)
2)
Carry out the Dockside commissioning procedure (see page 56). Display
the Pilot screen, move the helm, does the rudder indicator function?
Yes
go to step (4)
No
go to step (3)
3)
The rudder indicator on the Pilot screen will not function if invalid rudder
end and mid points have been entered. Check the rudder reference unit
installation (see page 91) is such that the voltage difference between the
port and starboard end stops is a minimum of 1.0 volt. After checking
repeat step (2).
4)
If the rudder has previously been successfully commissioned then the
fault is likely to be due to memory corruption. This may be due to a recent
change of software version or severe interference (e.g. lightning).
We recommend that you reset the Pilot computer (node 18) and attempt to re-
commission the Pilot. If this fails contact your local specialist dealer.
Summary of Contents for h3000
Page 1: ...www bandg com ...
Page 2: ......
Page 86: ...H3000 Pilot Handbook 86 HB 3001 03 DIP Switch Location DIP Switches ...
Page 94: ...H3000 Pilot Handbook 94 HB 3001 03 Continuous Drives Heavy Duty Power Supply Circuit Breaker ...
Page 95: ... H3000 Pilot Handbook 95 HB 3001 03 Linear Feedback Heavy Duty Power Supply Circuit Breaker ...
Page 96: ...H3000 Pilot Handbook 96 HB 3001 03 R Blk W G Scn Halcyon 2000 Compass ...
Page 97: ... H3000 Pilot Handbook 97 HB 3001 03 Halcyon Gyro Stabilised Compass ...
Page 98: ...H3000 Pilot Handbook 98 HB 3001 03 Direct Speed Input ...
Page 118: ...H3000 Pilot Handbook 118 HB 3001 03 P R S P R S P R S P R S ...