H3000 Pilot Handbook
19
HB-3001-03
OPERATING INFORMATION
SWITCHING ON
The H3000 Pilot has two power supplies (instrument and heavy duty rudder drive
supply) these are normally connected via circuit breaker. The Pilot computer and
Pilot displays are powered via the Fastnet network cable and share the same source
of power supply as the H3000 instrument system.
The hydraulic ram, rotary drive or hydraulic pump supplies are routed via the
Pilot computer. The heavy-duty supply is dedicated to the rudder drive unit and is
connected via a separate heavy-duty fuse or circuit breaker.
To switch the Pilot ON, proceed as follows:
• Switch ON the instrument supplies.
• Switch ON the heavy-duty power supply for the rudder drive unit.
The Pilot will only operate if both the heavy duty and instrument supplies are
switched ON.
Notes:
• If the Pilot Display indicates Fault 115 when engaged for the first time, check
that the heavy-duty drive supply is switched ON. If it is off switch ON the
heavy-duty supply and clear the fault message.
• If the Pilot Display shows Fault 104 when engaged, this indicates that there is
no boat speed input from the sensor. This is normal if the Pilot is switched on
at the dockside.
Summary of Contents for h3000
Page 1: ...www bandg com ...
Page 2: ......
Page 86: ...H3000 Pilot Handbook 86 HB 3001 03 DIP Switch Location DIP Switches ...
Page 94: ...H3000 Pilot Handbook 94 HB 3001 03 Continuous Drives Heavy Duty Power Supply Circuit Breaker ...
Page 95: ... H3000 Pilot Handbook 95 HB 3001 03 Linear Feedback Heavy Duty Power Supply Circuit Breaker ...
Page 96: ...H3000 Pilot Handbook 96 HB 3001 03 R Blk W G Scn Halcyon 2000 Compass ...
Page 97: ... H3000 Pilot Handbook 97 HB 3001 03 Halcyon Gyro Stabilised Compass ...
Page 98: ...H3000 Pilot Handbook 98 HB 3001 03 Direct Speed Input ...
Page 118: ...H3000 Pilot Handbook 118 HB 3001 03 P R S P R S P R S P R S ...