Example 2~
Single network cable. Processor switch to ON. Terminated at processor
unit via switch as shown. Add a network terminator to the last junction box at the
end.
Processor
Switch to ' ' (On Position)
Fastnet Cable
Network Terminator
Insert
Grommet Plug
G W
Scn
Blk R
Network Terminator
Note:
A network terminator must be fitted across the green and white network
data wires of the last unit or junction box at each end of the network cable. When
adding more displays or units to the network, ensure that the terminator is moved
to the ends of the network cable. Never fit more than two terminators on the
network.