background image

UK

Do not install the bollard in an explosive atmosphere. The presence of flammable gases or fumes constitutes a
grave danger.

It is suggested to store the automated device in closed places.

WARNING: IMPORTANT SAFETY INSTRUCTIONS.

It is important to follow these instructions in order to safeguard people. 
Incorrect installation or improper use of the product may lead to serious harm to people.
Keep this instruction booklet and read it carefully before starting installation.

Typical installation of the TOUCHE bollard in a public place 
Before  connecting  all  the  electric  cables  to  the  control  unit,  all  the  bollard  safety  devices  and  visual  warning 
accessories must be installed: metal detector coils, traffic lights, emergency switches, radio receivers, reception 
antennas.

1 - Differential magnetothermal switch
2 - Control unit with radio receiver 
3 - Entrance metal detector
4 - Exit metal detector
5 - Anti-break-in protection cabinet
6 - Waterproof box for electrical connections to the exit inductive coil
7 - Underground inductive coil at exit
8 - Waterproof box for electrical connections to the entrance inductive coil  
9 - Underground inductive coil at entrance 
10 - Radio control
11- Accessory column
12 - Key selector
13 - Photocell
14 - Danger warning signs
15 - Red/green traffic light
16 - TOUCHE bollard
17 - Radio reception antenna
18 - Metal case to be cemented into the ground

ELECTRICAL EQUIPMENT (1a - 1b)

In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices.  Any repairs must be carried out by specialised personnel using 
original and certified materials. 
The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or lacking 
experience and knowledge, unless appropriately instructed.
Do not access the circuit board for adjustments and/or maintenance.

WARNINGS FOR THE USER

13

TOUCHE

Summary of Contents for GBD TOUCHE

Page 1: ...TOUCHE UK TOUCHE 120 275 Hydraulic rising bollards INSTRUCTIONS FOR INSTALLATIONS...

Page 2: ...TOUCHE 2 9 1b 1a 2 1 3 4 5 10 14 15 17 18 230V 10 50Hz 16 6 7 8 9 11 12 TOUCHE275 TOUCHE120 2 1 3 4 5 10 14 15 17 18 230V 10 50Hz 16 6 7 8 9 11 13 12...

Page 3: ...Yellow green 1 2 3 4 Grigio Grey Nero Black Marrone Brown Terra Ground COM Apertura Opening Chiusura Closing brown cable grey cable black cable opening COM closing brown cable grey cable black cable...

Page 4: ...20 10 17 14 15 13 16 12 11 HYDRAULIC CONTROL UNIT MOTOR POWER SUPPLY SENSOR BOARD POWER SUPPLY 1 2 3 4 5 6 7 8 9 10 m 1 2 3 4 5 6 7 8 9 10 m SENSOR BOARD POWER SUPPLY HYDRAULIC CONTROL UNIT MOTOR POWE...

Page 5: ...4 5 TOUCHE Exit coil Exit coil Entrance coil Entrance coil 9 5 1285 mm 300 mm 450 mm TOUCHE120 630x530 mm 300 mm 1440 mm TOUCHE275...

Page 6: ...6 6a TOUCHE 300 mm 406 mm 1 2 3 3 4 B 300 mm 200 mm 10 mm E D 4 5 5 6 F C A 1600 1650 mm 300 mm 100 mm 9 6b 300 mm 406 mm 1 2 3 3 4 B 300 mm 200 mm 10 mm E D 4 5 5 6 F C A 1600 1650 mm 300 mm 100 mm...

Page 7: ...7 7 8 TOUCHE D 33 mm B C A D 33 mm B C A TOUCHE120 TOUCHE275 A B B A PULL THE CABLES CAREFULLY PULL THE CABLES CAREFULLY...

Page 8: ...8 TOUCHE 9 10 11 12 GREASE TOUCHE120 TOUCHE120 TOUCHE120 TOUCHE275 TOUCHE275 TOUCHE275...

Page 9: ...9 TOUCHE 13 14 TOUCHE120 TOUCHE120 TOUCHE275 TOUCHE275...

Page 10: ...10 TOUCHE 15 B A 16 17 B A TOUCHE120 TOUCHE120 TOUCHE120 TOUCHE275 TOUCHE275 TOUCHE275...

Page 11: ...11...

Page 12: ...butalwayscallinqualified andauthorisedtechnicians The automated device is packed on Europallets and must be handled with the utmost care using approved pallet transportersorlifttrucks Checkthattheeart...

Page 13: ...eceiver 3 Entrancemetaldetector 4 Exitmetaldetector 5 Anti break inprotectioncabinet 6 Waterproofboxforelectricalconnectionstotheexitinductivecoil 7 Undergroundinductivecoilatexit 8 Waterproofboxforel...

Page 14: ...Resistance to impact without deformation Breakthrough resistance Manual lowering Annual cycles with 8 operating hours a day Heavy use Operator Type Hydraulic rising bollards Hydraulic rising bollards...

Page 15: ...disturbance that may condition the metal detector coils It is recommended to install the magnetic coil according to a rectangular perimeter with the longest side perpendicular to the movement directio...

Page 16: ...cable puller to run the electric cables through the tube in order not to damage them 14 Check that the top of the TOUCHE bollard is level using a spirit level If necessary adjust by turning the adjus...

Page 17: ...the unlocking key A 15 inthelockunderneathandthebollardwillautomaticallyretractintoitsseat For optimal system performance over time and in accordance with the safety regulations proper maintenance and...

Page 18: ...ckfunctioningoftheradiocontrolreceiver Gi Bi Di Srlreservestherighttochangethetechnicaldatawithoutpriornoticeinrelationtoproductdevelopment Intheeventofanymalfunction cutthepowertothesystemandcallinaq...

Page 19: ...HIDRAULIC RISING BOLLARDS TOUCHE Are in conformity with the following CEE Directives and that the following harmonised standards have been applied Data 30 09 09 S r l LVDDirective2006 95 CEandsubsequ...

Page 20: ...gn Installer company stamp Date Technician sign Date Notes Technician sign Installer company stamp Date Technician sign Date Notes Technician sign Installer company stamp Date Technician sign Date Not...

Page 21: ...21 TOUCHE NOTE...

Page 22: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC6518 10 2009 Re...

Reviews: