background image

    SET                                                                                                           

16/42

 

 

  END 

 

 

UPC- A   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.2 UPC-E 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM OPTION 

 

 

     None ( Default )   

 

 

 

2 bits                   

 

 

5 bits                   

 

 

ADDENDUM 

 

 

2 or 5 bits         

ITEM OPTION 

 

 

Disable 

 
 

 

READABLE 

 

 

 

                  Enable ( Default )

Summary of Contents for HY-70

Page 1: ...SET 0 42 END HY 70 HY 100 Long Range Barcode Scanner User s Manual...

Page 2: ...232 serial communication setting 7 2 2 Scanning mode selection 11 2 3 Beeper tone selection 13 2 4 Header and Trailer 14 3 Bar Code Parameters Setting 3 1 UPC A 16 3 2 UPC E 16 3 3 EAN 13 18 3 3 ISBN...

Page 3: ...e When the content is Ref Appendix in the OPTION line the scanner read the barcode in the appendix If setting more appendix barcode the scanner always read this barcode until the system couldn t setti...

Page 4: ...l the parameters back to default values 1 2 Show firmware version The reading of the FIRMWARE VERSION label will be shown firmware version 1 3 Show series number The reading of the SERIES NUMBER label...

Page 5: ...Choose the appropriate type of keyboard emulation by scanning the labels under the following labels Keyboard language selection Function key active ON OFF For IBM AT only Function keys can be concaten...

Page 6: ...board type selection Capital Lock ON OFF ITEM OPTION USA Default UK Germany French Spanish Italian Swiss LANGUAGE SELECTION Swedish OFF Default FUNCTION KEY ON Scan Code mode Default Alt mode KEYBOARD...

Page 7: ...SET 6 42 END Select the suitable code to match your keyboard caps lock status Num Lock ON OFF Inter Character delay for keyboard wedge This option governs delay time among consecutive characters...

Page 8: ...nsecutive messages 2 1 2 RS 232 Serial communication setting With this option of communication protocol you can tailor the scanner to meet the requirement of most systems ITEM OPTION OFF Default CAPS...

Page 9: ...onsecutive characters Inter Message delay for RS 232 ITEM OPTION None Enter Default Tab MESSAGE TERMINATOR for KB Execute 0 ms Default 100 ms 500 ms INTER MESSAGE DELAY for KB 1000 ms 600 bps 1200 bps...

Page 10: ...SET 9 42 END ITEM OPTION 0 ms Default 10 ms 50 ms INTER CHARACTER DEL AY for RS 232 100 ms 0 ms Default 100 ms ITEM OPTION 1 Default STOP BIT 2 None Default Even Odd Mark PARITY Space...

Page 11: ...for RS 232 1000 ms Message terminator For RS 232 Handshaking protocol The RS 232 scanner supports four handshaking protocols ACK NAK response time setting ITEM OPTION None CR LF Default CR LF H Tab S...

Page 12: ...Simultaneously The scanner decoded only once when put the barcode on the scan line If put the barcode on the scan line again the scanner decoded again Then the scanner will turn off for next pressing...

Page 13: ...SET 12 42 END ITEM OPTION Trigger mode Default Auto scan mode Alternate mode Repeat mode Testing mode SCANNING MODE SELECTION Turbo trigger mode...

Page 14: ...SET 13 42 END 2 3 Beeper selection ITEM OPTION Very low Low Default Medium BEEPER TONE High Disable Very short Short Medium BEEPER SOUND DURATION Long Default...

Page 15: ...trailer is not greater than 10 digits 1 Select either header or trailer you are going to program by scanning the corresponding label 2 Scan the character you want from the enclose ASCII table to set...

Page 16: ...N Disable Default FORCE UPC A TO EAN 13 FORMAT Enable Disable TRANSMITTING CHECK DIGIT Enable Default Disable NOT TRANSMITTING LEADING CHARACTER Enable Default 0 Default CUT FRONT Ref Appendix 0 Defau...

Page 17: ...SET 16 42 END UPC A 3 2 UPC E ITEM OPTION None Default 2 bits 5 bits ADDENDUM 2 or 5 bits ITEM OPTION Disable READABLE Enable Default...

Page 18: ...ND Disable Default IDENTIFIER CODE Ref Appendix Disable Default FORCE UPC E TO UPC A FORMAT Enable Disable TRANSMITTING CHECK DIGIT Enable Default 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK R...

Page 19: ...NG LEADING CHARACTER Enable Default None Default 2 Bits 5 Bits ADDENDUM 2 or 5 Bits ITEM OPTION Disable READABLE Enable Default Disable Default IDENTIFIER CODE Ref Appendix Disable TRANSMITTING CHECK...

Page 20: ...SET 19 42 END EAN 13 EAN 13 transfer to ISBN ISSN ITEM OPTION 0 Default CUT BACK Ref Appendix None Default 2 Bits 5 Bits ADDENDUM 2 or 5 Bits Disable Default TRANSFER TO ISBN ISSN Enable...

Page 21: ...isable READABLE Enable Default Disable Default IDENTIFIER CODE Ref Appendix Disable TRANSMITTING CHECK DIGIT Enable Default 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix None Defaul...

Page 22: ...ABLE Enable Default Parameters setting ITEM OPTION Disable Default IDENTIFIER CODE Ref Appendix Disable Default CALCULATING Enable Disable TRANSMITTING CHECK DIGIT Enable Default Disable Default CONCA...

Page 23: ...haracters 3 6 Codabar ITEM OPTION 0 MAX Ref Appendix 00 64 Default 32 Standard Default PARAMETERS Full ASCII Disable Default START STOP CHARACTER TRANSMISSION Enable ITEM OPTION Disable READABLE Enabl...

Page 24: ...able TRANSMITTING CHECK DIGIT Enable Default 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix ABCD ABCD Default abcd abcd START STOP CHARACTER TYPE abcd tn e Disable Default START STOP...

Page 25: ...ult Disable Default IDENTIFIER CODE Ref Appendix Disable Default CALCULATING Enable Disable TRANSMITTING CHECK DIGIT Enable Default 0 MIN Ref Appendix 0 64 Default 0 0 MAX Ref Appendix 0 64 Default 32...

Page 26: ...able Default Disable Default IDENTIFIER CODE Ref Appendix Disable Default CALCULATING Enable Disable TRANSMITTING CHECK DIGIT Enable Default Disable Default FNC2 CONCATENATION Enable Disable Default U...

Page 27: ...SET 26 42 END Code 128 ITEM OPTION 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix 0 MIN Ref Appendix 0 64 Default 0 0 MAX Ref Appendix 0 64 Default 32...

Page 28: ...e Default Disable Default IDENTIFIER CODE Ref Appendix Disable Default CALCULATING Enable Disable TRANSMITTING CHECK DIGIT Enable Default 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Append...

Page 29: ...2 of 5 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix ITEM OPTION Disable READABLE Enable Default Disable Default IDENTIFIER CODE Ref Appendix 0 MIN Ref Appendix 0 64 Default 0 0 MAX...

Page 30: ...of 5 ITEM OPTION Disable Default READABLE Enable Disable Default IDENTIFIER CODE Ref Appendix 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix 0 MIN Ref Appendix 0 64 Default 0 0 MAX...

Page 31: ...ADABLE Enable Disable Default IDENTIFIER CODE Ref Appendix Disable Default CALCULATING Enable Disable TRANSMITTING Enable Default 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix 0 MIN...

Page 32: ...t IDENTIFIER CODE Ref Appendix Calculate 2 bits But not transmit CHECK DIGIT Not calculate Default Calculate 2 bits Transmit 1 bit Calculate 2 bits Transmit 2 bits Calculate 1 bit But not transmit Cal...

Page 33: ...SET 32 42 END MSI Plessey ITEM OPTION 0 Default CUT FRONT Ref Appendix 0 Default CUT BACK Ref Appendix 0 MIN Ref Appendix 0 64 Default 0 0 MAX Ref Appendix 0 64 Default 32...

Page 34: ...SET 33 42 END APPENDIX CODE 39 FULL ASCII BAR CODE TABLE NUL ACK SOH BEL STX BS ETX HT EOT LF ENQ j...

Page 35: ...SET 34 42 END VT DC2 FF DC3 CR DC4 SO NAK SI SYN DLE ETB DC1...

Page 36: ...SET 35 42 END CAN US EM SP SUB ESC FS GS RS...

Page 37: ...SET 36 42 END 0 1...

Page 38: ...SET 37 42 END 2 9 3 4 5 6 7 8...

Page 39: ...SET 38 42 END F G A H B I C J D K E...

Page 40: ...SET 39 42 END L S M T N U O V P W Q X R...

Page 41: ...SET 40 42 END Y Z a b c d e _...

Page 42: ...SET 41 42 END f m g n h o i p j q k r l...

Page 43: ...SET 42 42 END s z t u v w x DEL y...

Reviews: