background image

4

6. Master control input/output (A or B)

- The AV1260 is designed to provide independent control for two groups

of amplifier channels, Group A has control over amplifier channels 1-6, while Group B has control over amplifier
channels 7-12.

Master control A

allows for single switching of the amplifier audio mute on/off feature on any pair

of amplifier channels (1-2, 3-4 or 5-6) with it’s DIP switch setting configured for Amp off and Sense off. Similarly,

Master control B

allows for single switching of the amplifier audio mute on/off feature on any pair of amplifier

channels (7-8, 9-10 or 11-12) with it’s DIP switch setting configured for Amp off and Sense off. The Master control
output is a pass through of the Master control input. Master control out A could be sent to Master control input B
to allow any combination of the 12 amplifier channels muting to be controlled via a single source. The control
input circuit is designed to work as Tip Pos. (+) and Ring Neg. (-). A control source capable of sourcing a
minimum of 5 VDC @ 1 mA is recommended, and is compatible with up to 24V AC or DC.

(The Master control outputs DO NOT source any voltage directly, they only PASS through the input
voltage at their receptive inputs).

7. Bus inputs and outputs (A or B)

- In a similar fashion to the Master control inputs, the AV1260 has provisions

for two independent stereo audio distribution busses, BUS A and BUS B. These are independent stereo audio
inputs which allow BUS A (group A) to source audio to amplifier channels (1-2, 3-4 or 5-6) with it’s DIP switch
‘BUS’ set to ON, while BUS B (group B) is used to source audio to amplifier channels (7-8, 9-10 or 11-12) with it’s
DIP switch ‘BUS’ set to ON. Simultaneously, buffered BUS A and B stereo audio outputs are provided to allow
audio distribution and system expansion.

8. AC Input receptacle

- Connect the supplied AC power cord to the amplifier.

9. Speaker outputs

- ‘Phoenix’ speaker connectors for easy speaker hook-up. To prevent damage to the

speakers or amplifier, always verify there is no possibility of shorting multiple speaker terminals or loose wire
strands together.

DIP SWITCH SETTING

Each pair of amplifiers have their own set of four DIP switches. The function of each switch is described below:

AMP ON:

(ON is the factory default setting for all amplifier pairs)

Amplifier pairs with DIP switch ‘AMP’ set to ‘ON’, have the remote Master and Channel switching of
the amplifier audio mute on/off feature disabled. When remote amplifier audio muting is desired by
either the Master or ‘Local’ Channel control input, the ‘AMP’ switch must be set to the ‘Off’ position.

SENSE OFF:

(OFF is the factory default setting for all amplifier pairs)

Amplifier pairs with DIP switch ‘SENSE’ set to ‘ON’, have the remote Master and Channel switching of
the amplifier audio mute on/off feature disabled. Amplifier pairs set to use ‘SENSE’ will mute
automatically after a delay of three minutes once no audio signal has been detected. The sense circuit
monitors the amplifiers selected audio, i.e.. ‘Local’ or ‘BUS’ mono or stereo. When remote amplifier audio muting
is desired by either the Master or ‘Local’ Channel control input, the ‘SENSE’ switch must be set to the ‘Off’
position. When the AMP ON feature is desired or automatic muting of the amplifier pairs is not desired, or if the
audio signal is erratic, the ‘SENSE’ switch must be set to the “Off’ position.

L + R:

(OFF is the factory default setting for all amplifier pairs)

Amplifier pairs with DIP switch ‘L + R’ (mono) set to ‘ON’, have the sum of the selected audio inputs,
i.e.. ‘Local’ or ‘BUS’, processed into a composite mono signal source for both amplifier channels.
When mono is not desired, or independent channel amplification of the amplifier pairs is necessary,
the ‘L + R’ switch must be set to the ‘Off’ position

BUS:

(OFF is the factory default setting for all amplifier pairs)

Amplifier pairs (channels 1-2, 3-4 and 5-6), with DIP switch ‘BUS’ set to ‘ON’, have their inputs
sourced from the audio signals present at the BUS inputs. When the BUS feature is not desired and
the amplifier pair is to be sourced at the ‘Local’ audio inputs, the ‘BUS’ switch must be set to the ‘Off’.

Summary of Contents for AV1260

Page 1: ...P N12931 0403 B K Components Ltd AV1260 Owner s Manual...

Page 2: ...ii B K Components Ltd 2100 Old Union Road Buffalo New York 14227 2725 Phone 1 800 543 5252 or 716 656 0026 Fax 716 656 1291 E mail info bkcomp com Web www bkcomp com...

Page 3: ...Channel Control Muting 5 Master Control Muting 5 Level Control 5 Input Connections 6 Output Connections 6 Level Control Defeat 7 Jumper Settings 7 High Current Mono Usage 8 System Installation 9 Makin...

Page 4: ...ce the unit is resting on We advise against removing or altering feet Do not stack anything on top of the amplifier processor source etc Leave a minimum of 2 clearance from the top of the amplifier to...

Page 5: ...s is the default factory configuration Using the audio distribution BUS DIP switches allow independent configuration for up to 6 pairs of mono or stereo with independent automatic audio sense muting p...

Page 6: ...ifier audio mute on off feature The control input circuit is designed to work as Tip Pos and Ring Neg A minimum of 5VDC 1 mA is recommended and is compatible with up to 24V AC or DC 3 Dip switches Eac...

Page 7: ...nt damage to the speakers or amplifier always verify there is no possibility of shorting multiple speaker terminals or loose wire strands together DIP SWITCH SETTING Each pair of amplifiers have their...

Page 8: ...inimum of 5 VDC 1 mA is recommended and is compatible with up to 24V AC or DC The Master control outputs DO NOT source any voltage directly they only PASS through the input voltage at their receptive...

Page 9: ...and how they may be used to connect to another amplifier OUT 1 source is the same signal as IN 1 OUT 2 source is the same signal as IN 2 BUS inputs are buffered and sent to the BUS outputs OUTPUT CON...

Page 10: ...rranging these jumpers allows configuring the amplifier for use without a level control required for proper operation using paralleled output channels Figure 6 When reconfiguring the AV1260 to NOT USE...

Page 11: ...nels to use the NO VOL jumper terminals Figure 8 The desired speaker output terminals on the AV1260 rear panel must now be paralleled in order to complete the setup Connect the terminals for all desir...

Page 12: ...is recommended that you locate a separate AC power outlet for the amplifier one that is not shared by any other audio component in the system or any other household component This will eliminate the...

Page 13: ...weak 1 Speakers connected out of phase 1 Check all connections making sure that cables are connected to and to Loud hum or buzz on one or more channels 1 Poor ground connection in inter connect cable...

Page 14: ...eak 16 Amps Slew rate 14 V sec Dynamic headroom 1 0 dB S N A weighted 95 dB Voltage gain 28 Line voltage 120 220 240 VAC switchable Dimensions O A 17 w X 14 5 d X 5 75 h Weight 38 lbs max Power consum...

Page 15: ...des B K delivers exceptional value to its customers But what is Upgradability Upgradability is not a guarantee we define it as a philosophy of designing and manufacturing products so that as audio tec...

Page 16: ...13 WWW BKCOMP COM B K Components Ltd 2100 Old Union Road Buffalo New York 14227 Phone 716 656 0026...

Reviews: