B K
&
S
B
IMPLY
ETTER!
23
AM Loop Antenna
Three internal AM/FM tuners included in the CT 600.3 and 300.3. A single tuner in
included with the CT 600.1
.
The AM tuner requires a AM loop antenna oriented for best
tuner frequency reception. The signals are internally split to eliminate the need for multi-
ple antennas in multi-tuner Receivers.
FM Antenna
Three internal AM/FM tuners included in CT 600.3 and 300.3. A single tuner in included
with the CT 600.1
.
The tuner requires a single coaxial FM antenna oriented for best
tuner frequency reception. The signals are internally split to eliminate the need for multi-
ple antennas in multi-tuner Receivers.
Factory Reset
Sometimes a factory reset is necessary in order to clear problematic symptoms sometimes experienced in
the field. A factory reset will clear all system settings, all presets, and all serial macros. A factory reset will
also clear any information backed up onto the EEPROM that may have been accomplished by a Memory
Backup.
Factory Reset On a CT 600.3/600.1/300.3 through the Menu
A factory reset may be set from the on screen menu system. OSD menus may be viewed through the Zone
A video output. RESET is located in the Memory/Backup restore option. Using a IR control device in Zone A
press [menu - 5 - left - enter]. A factory reset takes approximately 60 seconds to execute.
Factory Reset On a CT 600.3/600.1/300.3 through Quick Tools
Connect to the B&K Quick Tools software (available on www.bkcomp.com). Select the appropriate baud rate
and com port then click on Com Start (appropriate IP address and port if using networking availability).
When connected to the unit, click on Reset Unit. A factory reset takes approximately 60 seconds to execute.
A “(00,U,S,0=’BKC-DIP ACTIVE;)” message will appear in the RS-232 receive window when the reset is
completed.
Factory Reset On a CT 600.3/600.1/300.3 through RS-232
Connect to the B&K Suite software or any hyperterminal software. If using B&K Suite software, when unit is
detected click on BK terminal. Type in command (FF,X,7;) and send command to unit. A factory reset takes
approximately 60 seconds to execute. A “(00,U,S,0=’BKC-DIP ACTIVE;)” message will appear in the RS-232
receive window when the reset is completed.
Additional Connections
RJ-45 Adapters
Ethernet
- Used for flashing the software of the CT Receiver or network control.
Please see the B&K website at www.bkcomp.com for more information.
RS-232 I/O
- Used for serial control using B&K Hardware Quick Tools and setup of CT
Receiver using BK Suite.