BK Suite Setup and Overview
4.
Create and save the system setup file using either the Basic Setup menu or the Advanced Setup
menu of BK Suite See Page 32.
5.
Either let the program automatically scan com ports 1 through 4 at all baud rates or manually
configure the com port and baud rate settings as shown below.
6.
Connect the PC to the B & K product run the device investigator. The unit will be found and con-
nection will be established.
7.
Once a live connection has been established, open the file previously created. Once the file is
opened, it will overwrite the settings in the B & K product with the settings configured in the setup
file.
Note: While a live connection is established with a CT Receiver, any changes made in BK Suite will
immediately update inside the unit itself. The system file should be saved on your computer as a
backup. System settings are normally stored with a .bks extension (Advanced and Basic setup) while
presets are stored with .bkp extension (Preset editor) and macro files are stored with a .bkm extension