background image

Remote System

User’s Guide

https://www.b-plus-kk.jp/     

E-mail  seles

@

b-plus-kk.jp

4.4

Φ

45.0

(3.0)

55.0

55.0

45.0

30.0

Remote sensor sysytem

24 signal transmission / Compact shape

24V1A type

Output sensor:RS24E-424N-PU-_ _ ,

 RS24E-424P-PU-_ _

Transmitter : RS24T-424-PU-_ _

【Function of each component】

Detector : 

 Connects Detector sensor (max.24) and transmits the detected signals to Transmitter.

Transmitter : 

Provides power for Detector, also passes detected signals from Detector to Output Sensor. 

Output Sensor : Puts out detected signal to external controller, also sends power for operating of Detector and Transmitter.  

System configuration

Dimension

Specification of the System

Available sensors

LED indication

■ Status LED(Green)

■ In zone LED (Orange)

RS24E

RS24T

Host device

External Power 

Unit(24V DC )

DC3-wire, 

sensor

The in zone LED lights up when the transmission part and the output part are in a confronting state and communication is possible.

Typical Transmitting Diagram 

(Supply voltage at 24V /non-flush mount)

X:Center offset(mm)
Y:Operating distance(mm)

2021.12.21

[ Detector ]

Detected 

signal

Detected 

signal

max.24 signals

Power 

supply

Power

supply

24V DC

[ Transmitter ]

Signal

transmission

[ Output sensor ]

LED

Lighting pattern

Meaning

ON

-

-

The power supply is supplied.

OFF

-

-

The power supply is not supplied.

Blink

Slow

(1.5 sec)

Off time of the LED is long Anomalous temperature

Blink

Lighting time of the LED is long Oscillation circuit overcurrent.

Blink

Mid.Speed

(0.6 sec)

Off time of the LED is long Supply voltage is high.

Blink

Lighting time of the LED is long Supply voltage is low.

Blink

High speed

(0.2 sec)

The LED flashes at the 

same interval

Short circuit protection.

ON

OFF time of the 

LED is long

Lighting time of the 

LED is long

ON

OFF

OFF

Operating area

Operating area

Drive current ≦ 0.5A

Output sensor:

RS24E-424N-PU-_ _(NPN)

 

           

Transmitter:     

RS24T-424-PU-_ _

               

    T319301Fe

Supply voltage

24V DC

Total  currenconsumptoion

≦ 1A

Residual voltage

≦ 6.5V

Load current

  -

*¹【RB】represents robot cable specifications.
*² Indicates the time from when the remote and base sections are energized in the transmittable area to when non-contact signal transmission is possible.
*³ Metal protection is a function to prevent metal heat generation when facing metal, and is not guaranteed to work on all metals. Do not intentionally place metal against the communication surface.

RS24E-424P-PU-_ _(PNP)

Type          

RS24T-424-PU-_ _

Applicable sensor DC 3-wire sensor
Drive voltage

(Output voltage) 24V ± 1.5V DC
Drive current total ≦ 1A
Input signals

24(SI1… 24) and a switching signal(NPN / PNP)

Operating 

distance

in the case of 1A 0...4mm 
in the case of 0.5A 0...6.5mm  

Center offset (1A)

± 6mm   :Transmission distance is within 3mm
± 2.5mm:Transmission distance 3...4mm

Center offset(0.5A)

± 8mm   :Transmission distance is within 4.5mm 
± 3mm    :Transmission distance 4.5...6.5mm

Operating temperature

0...+50℃

Protection class IP67
Cable

PUR φ 8.6x2(2x0.5mm

2

+13x0.18 mm

2

)+(12x0.18 mm

2

【RB】

Material

   Case

Polyurethane

  Heat sink Aluminum

Weight

Body 165g +Cable 105g/m x2pcs.

Type 

        NPN

RS24E-424N-PU-_ _

        PNP

RS24E-424P-PU-_ _

Supply voltage(Input voltage)

24 V DC ± 5 %

 

Current 

consumption

active

Max 1.5 A (with 1A drive)

static

Max 0.1 A (when not facing)

Number of output signals 24+1(In zone)
Load current

≦ 50mA/ 1output

Startup time

≦ 0.2sec*²

Frequency of operation

300Hz

LED indication

Status (Green), In zone (Orange)

Operating temperature

0...+50℃

Protection class

IP67

Protection circuit

Reverse connection protection, overheat protection, 

short circuit protection,

 

overcurrent  protection  Output  surge  absorption 

protection, head metal facing protection *³

Cable

PUR φ 8.6x2(2x0.5mm

2

+13x0.18 mm

2

)+(12x0.18 mm

2

Material

   Case

Polyurethane

   Heat sink

Aluminum

Weight

Body 165g+ Cable 105g/m x 2pcs.

Use a sensor that operates correctly within the 

conditions in the table below.

In zone LED

Status

 LED

(L)

Cable 1

Cable 2

Marking tube

Drive current ≦ 1A

Y

X

(3.0)

55.0
45.0

Φ

4.4

45.0

55.0

30.0

Cable 1

Cable 2

L=Cable length

The notation in meters to

the end of the model

・・・PU-02 ⇒ 2m 

max. 5m

(Transmitter,Outputsensor)

(L)

0.5A

X

Y

mm

-12 -9 -6 -3

0

10

8
6
4
2

12

9

6

3

1A

X

Y

mm

-8 -6 -4 -2 0

5
4
3
2
1

8

6

4

2

RS24T-424-PU-_ _

Cable 1 (with marked tube)

    24 V

WH

  Output0V

  PaleBU

Polarity switching POL

BK

Cable 2

Input 1(SI1)

BN

 Input 13(SI13) GN *■ ■

Input 2(SI2)

RD

 Input 14(SI14) BU *■ ■

Input 3(SI3)

OG

 Input 15(SI15) VT *■ ■

Input 4(SI4)

YE

 Input 16(SI16) GY *■ ■

Input 5(SI5)

GN

 Input 17(SI17) BN **■  ■

Input 6(SI6)

BU

 Input 18(SI18) RD **■  ■

 Input 7(SI7)      VT

   Input 19(SI19) OG **■  ■

 Input 8(SI8)      GY

   Input 20(SI20) YE **■  ■

 Input 9(SI9) BN *■ ■    Input 21(SI21) GR **■  ■
 Input 10(SI10)RD *■ ■    Input 22(SI22) BU **■  ■
 Input 11(SI11)OG *■ ■    Input 23(SI23) VT **■  ■
 Input 12(SI12)YG *■ ■    Input 24(SI24) GY **■  ■

RS24E-424N/P-PU_ _

Cable 1 (with marked tube)

    Input+24 V

WH

  Input 0V

PaleBU

  In zone Iz

BK

Cable 2

Output1(SO1)

BN

Output13(SO13) GN *■ ■

Output2(SO2)

RD

Output14(SO14) BU *■ ■

Output3(SO3)

OG

Output15(SO15) VT *■ ■

Output4(SO4)

YE

Output16(SO16) GY *■ ■

Output5(SO5)

GN

Output17(SO17) BN **■  ■

Output6(SO6)

BU

Output18(SO18) RD **■  ■

Output7(SO7)      VT

 Output19(SO19) OG **■  ■

Output8(SO8)      GY

 Output20(SO20) YE **■  ■

Output9(SO9) BN *■ ■  Output21(SO21) GR **■  ■
Output10(SO10)RD *■ ■  Output22(SO22) BU **■  ■
Output11(SO11)OG *■ ■  Output23(SO23) VT **■  ■ 
Output12(SO12)YE *■ ■  Output24(SO24) GY **■  ■

Wiring color

■ Polarity switch POL is used to switch the polarity (NPN/PNP) of the sensor connected to the transmission unit.

Check the wiring diagram, and wire it according to the sensor to be connected. If it is not wired, no signal will be detected.

■ When shipped from the factory, the unused core wire of the cable is cut. If the cable is shortened for wiring reasons, the unused 

core wire will be exposed. If you shorten the cable for wiring reasons, the unused core wire will be exposed, so please take care 

not to short-circuit the cable. Unused wires are as follows: Cable 1: Green*, Blue*, Purple*. 

Cable 2: brown*, red*, orange*, yellow*, white, empty. (* indicates a wire with ■ ■ or ** printed on the core wire of each color.) 

 

Wiring Diagram

<When connecting a 3-wire NPN type detection sensor>

Detection sensor

 (NPN)

Detection sensor

  (DC2W)

(+)

出力

POL

(+)

SI

RS24T

Detection sensor

 (PNP)

(+)

出力

POL

(+)

SI

RS24T

(+)

POL

(+)

SI

RS24T

Detection sensor

  (DC2W)

(+)

POL

(+)

SI

RS24T

1 ~ 2 KΩ

PLC

RS24E

(+)

Iz

SO

<When connecting a 3-wire PNP type detection sensor>

<In case of 2-wire detection sensor connection (NPN setting)>

<In case of 2-wire detection sensor connection (PNP setting)>

<Connecting to an external PLC, etc.>

1 ~ 2 KΩ

When wiring, please check the wiring diagram carefully 

to ensure that the wiring is correct.

When connecting a DC 2-wire sensor, wire a resistance of 

about 1 to 2kΩ.

The following is an explanation of the protection functions provided.
Reverse connection protection ... When 24V and 0V are connected in reverse on the power line of the output section, this function turns off the output for a certain 

period of time to protect the circuit.
Overheat protection ... is a function that measures the temperature inside the output section and stops the power supply when the temperature exceeds a certain level. 

When the temperature drops, it restarts.
Short-circuit protection ... This function turns off the output for a certain period of time to protect the circuit when a current exceeding the specification flows through 

the signal output line due to wiring without load.
Overcurrent Protection ... This function detects the current inside the output section and stops transmitting for a certain period of time when the current exceeds a 

certain value, thereby protecting the circuit.
Output surge absorption protection...A surge absorption circuit is built in to protect the output circuit.
Head metal confrontation protection ... This function protects the circuit by stopping transmission for a certain period of time when metal is detected.

Protection function

Reviews: