Technical data • Complete system
24
Panel PC 2100 swing arm user's manual V1.00
2.2.2 Humidity
The following table lists the minimum and maximum relative humidity values for the individual components that
are relevant for the humidity limitations of a complete system. The lowest and highest common values are always
used when establishing these limits.
Display type
Model number
Operation
Storage/Transport
15.0" single-touch
5AP92D.1505-0x
8 to 90%
8 to 90%
19.0" single-touch
5AP92D.1906-0x
5 to 90%
5 to 90%
18.5" multi-touch
5AP93D.185B-0x
5 to 90%
5 to 90%
18.5" multi-touch with keys
5AP99D.185B-0x
5 to 90%
5 to 90%
21.5" multi-touch
5AP93D.215C-0x
10 to 90%
10 to 90%
21.5" multi-touch with keys
5AP99D.215C-0x
10 to 90%
10 to 90%
21.5" multi-touch with keys
5AP99D.215I-0x
10 to 90%
10 to 90%
24.0" multi-touch
5AP93D.240C-0x
5 to 90%
5 to 90%
24.0" multi-touch with keys
5AP99D.240C-0x
5 to 90%
5 to 90%
Table 14: Display units - Humidity
Component
Model number
Operation
Storage/Transport
System units
5PPC2100.BYxx-001
5 to 90%
5 to 95%
5CFAST.xxxx-00
Max. 85% at 85°C
Max. 85% at 85°C
CFast cards
5CFAST.xxxx-10
10 to 95%
10 to 95%
5ACCIF01.FPLS-000
5 to 90%
5 to 95%
Interface options
5ACCIF01.FPSC-000
5 to 90%
5 to 95%
Table 15: System units, IF options, CFast cards - Humidity
The specifications listed correspond to the relative humidity at an ambient temperature of 30°C. More detailed
information about specific temperature-dependent humidity values can be found in the technical data for the indi-
vidual components.
2.2.3 Vibration
The following table provides an overview of the maximum vibration specifications of the complete system. The use
of individual components may result in limitations.
Panel PC
Operation
Storage
1)
Transport
1)
Continuous
Periodic
With CFast card
9 to 200 Hz: 1 g
9 to 200 Hz: 1 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
Table 16: Vibration
1)
This value applies to a device in its original packaging.
2.2.4 Shock
The following table provides an overview of the maximum shock specifications of the complete system. The use
of individual components may result in limitations.
Panel PC
Operation
Storage
1)
Transport
1)
With CFast card
15 g, 11 ms
30 g, 6 ms
30 g, 6 ms
Table 17: Shock
1)
This value applies to a device in its original packaging.
2.2.5 Protection
The Panel PC 2100 swing arm device is rated IP65 in accordance with EN 60529 on all sides under the following
conditions:
•
The Panel PC 2100 swing arm device is installed correctly (see "Panel PC 2100 - Installation" on page
83)
•
All covers and components are installed on the interfaces and slots.
•
All environmental conditions are being observed.