X20 system modules • Fieldbus CPUs • X20XC0201, X20XC0202, X20XC0292
X20 system User's Manual 3.10
1753
4.21.2.7 Ethernet interface (IF2)
Figure 572: X20 compact CPUs - Ethernet interface for X20CP0291 and X20CP0292
The X20XC0292 is equipped with an Ethernet interface. The connection is made using a 100 BASE-T twisted pair
RJ45 socket.
Pinout
Pinout
Interface
Pin
Ethernet
1
RXD
Receive data
2
RXD\
Receive data\
3
TXD
Transmit data
4
Termination
5
Termination
6
TXD\
Transmit data\
7
Termination
1
Shielded RJ45 port
8
Termination
Table 530: RJ45 port - Pinout
Information about cabling X20 modules with an Ethernet interface can be found in the module's download section
Information:
The Ethernet interface (IF2) is not suited for POWERLINK.
Starting with operating system version 1.07, CPUs have a default IP address.
IP address:
192.168.0.1
Subnet mask:
255.255.0.0
4.21.2.8 Slot for fieldbus modules
Up to two fieldbus modules can be connected to the left side of the Fieldbus CPUs depending on the CPU base:
CPU base
Slots for fieldbus modules
X20BB32, X20BB37
1
X20BB42, X20BB47
2
Table 531: X20 Fieldbus CPUs - Slots for fieldbus modules depending on CPU base
The X20 system can be connected to various bus and network systems by selecting the appropriate fieldbus
modules. The following fieldbus modules can be operated with the CPUs:
Module
Description
X20IF1020
X20 interface module, 1 RS232, max. 115.2 kbit/s, electrically isolated
X20IF1030
X20 interface module, 1 RS485/RS422, max. 115.2 kbit/s, electrically isolated
X20IF1041-1
X20 interface module for DTM configuration, 1 CANopen master interface, electrically isolated
X20IF1043-1
X20 interface module for DTM configuration, 1 CANopen slave interface, electrically isolated
X20IF1051-1
X20 interface module for DTM configuration, 1 DeviceNet scanner interface, electrically isolated
X20IF1053-1
X20 interface module for DTM configuration, 1 DeviceNet slave (adapter) interface, electrically isolated
X20IF1061
X20 interface module, 1 Profibus DP master interface, max.12 Mbit/s, max. 3.5 KB input data and max. 3.5 KB
output data, electrically isolated
X20IF1061-1
X20 interface module for DTM configuration, 1 PROFIBUS DP V1 master interface, electrically isolated
X20IF1063
X20 interface module, 1 Profibus DP slave interface, max.12 Mbit/s, electrically isolated
X20IF1063-1
X20 interface module for DTM configuration, 1 PROFIBUS DP V1 slave interface, electrically isolated
X20IF1074
X20 interface module for SGC, 1 CAN interface, max. 1 Mbit/s, electrically isolated,...
X20IF10A1-1
X20 interface module for DTM configuration, 1 ASi master interface, electrically isolated
X20IF10D1-1
X20 interface module for DTM configuration, 1 EtherNet/IP scanner interface, electrically isolated
X20IF10D3-1
X20 interface module for DTM configuration, 1 EtherNet/IP slave interface, electrically isolated
X20IF10E1-1
X20 interface module for DTM configuration, 1 PROFINET RT controller (master), electrically isolated
X20IF10E3-1
X20 interface module for DTM configuration, 1 PROFINET RT device (slave), electrically isolated
X20IF10G3-1
X20 interface module for DTM configuration, 1 EtherCAT slave interface, electrically isolated
X20IF10H3-1
X20 interface module for DTM configuration, 1 Sercos III slave interface, electrically isolated
Table 532: X20 fieldbus CPUs - Possible fieldbus modules