Coated modules • Module overview: Grouped
X20 system User's Manual 3.10
2487
Product ID
Short description
on page
Other functions
X20 potential distributor, coated, 6x GND, 6x 24 VDC, with supply option, integrated microfuse
Power supplies
X20 power supply module, coated, for internal I/O supply
X20 power supply module, coated, for internal I/O supply, integrated microfuse
X20 power supply module, coated, for X2X Link and internal I/O supply
X20 power supply module, coated, for X2X Link and internal I/O supply integrated microfuse
System modules for bus controllers
X20 bus base, coated, for X20 base module (BC, HB, etc.) and X20 power supply module, X20 locking plates
(left and right) X20AC0SL1/X20AC0SR1 included
X20 power supply module, coated, for bus controller and internal I/O supply, X2X Link supply
System modules for expandable bus controllers
X20 bus base, coated, for X20 base module (BC, HB, etc.) and X20 power supply module, with one expan-
sion slot for an X20 add-on module (IF, HB, etc.), X20 locking plates (left and right) X20AC0SL1/X20AC0SR1
included
X20 bus base, coated, for X20 base module (BC, HB, etc.) and X20 power supply module, with 2 expansion slots
for 2 X20 add-on modules (IF, HB, etc.), X20 locking plates (left and right) X20AC0SL1/X20AC0SR1 included
System modules for the X20 hub system
X20 hub expansion module, coated, integrated 1-port hub, for fiber optic cable
X20 hub expansion module, coated, integrated 2-port hub, 2x RJ45
X20 hub expansion module, coated, integrated 2-port hub, for fiber optic cable
X20 power supply module, coated, for standalone hub and compact link selector
System modules for the X20 redundancy system
X20 hub expansion module, coated, integrated active 2-port hub, 2x RJ45
Temperature measurement
X20 temperature input module, coated, 4 inputs for resistance measurement, PT100, PT1000, resolution 0.1°C,
3-wire connections
X20 temperature input module, coated, 6 thermocouple inputs, Type J, K, N, S, resolution 0.1°C
X20 CPUs
X20 CPU, coated, ATOM 0.6 GHz, 256 MB DDR2 RAM, 1 MB SRAM, removable application memory: Compact-
Flash, 1 insert slot for X20 interface modules, 2 USB ports, 1 RS232 interface, 1 Ethernet interface 10/100/1000
Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot cover and X20 locking
plate (right) X20AC0SR1 included, order application memory separately.
X20 CPU, coated, ATOM 1.6 GHz, 512 MB DDR2 RAM, 1 MB SRAM, removable application memory: Compact-
Flash, 1 insert slot for X20 interface modules, 2 USB ports, 1 RS232 interface, 1 Ethernet interface 10/100/1000
Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot cover and X20 locking
plate (right) X20AC0SR1 included, order application memory separately.
X20 CPU, coated, ATOM 0.6 GHz, 256 MB DDR2 RAM, 1 MB SRAM, removable application memory: Compact-
Flash, 3 insert slots for X20 interface modules, 2 USB ports, 1 RS232 interface, 1 Ethernet interface 10/100/1000
Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot covers and X20 locking
plate (right) X20AC0SR1 included, order application memory separately.
X20 CPU, coated, ATOM 1.6 GHz, 512 MB DDR2 RAM, 1 MB SRAM, removable application memory: Compact-
Flash, 3 insert slots for X20 interface modules, 2 USB ports, 1 RS232 interface, 1 Ethernet interface 10/100/1000
Base-T, 1 POWERLINK interface, incl. supply module, 1 X20TB12 terminal block, slot covers and X20 locking
plate (right) X20AC0SR1 included, order application memory separately.
X20 electronics module communication
X20 interface module, coated, 1 RS422/485 interface, max. 115.2 kbit/s
X20 hub system
X20 base hub module, coated, integrated 2-port hub, 2x RJ45
X20 interface module communication
X20 interface module, coated, 1 RS422/485 interface, max. 115.2 Mbit/s, electrically isolated
X20 interface module coated, for DTM configuration, 1 PROFIBUS DP V0/V1 master interface, electrically iso-
lated
X20 interface module, coated, for DTM configuration, 1 PROFIBUS DP V1 slave interface, electrically isolated
X20 interface module, coated, 1 POWERLINK interface, managing or controlled node, integrated 2x hub, ring
redundancy function PRC function
X20 interface module, coated, for DTM configuration, 1 EtherNet/IP adapter (slave) interface, electrically isolated
X20 interface module, coated, for DTM configuration, 1 PROFINET RT device (slave) interface, electrically
isolated
X20 interface module, coated, 1 redundancy link interface 1000 Base-FX, CPU-CPU data synchronization for
controller redundancy
X20 interface module, coated, 1x link selector for POWERLINK cable redundancy, POWERLINK functions: -
Managing node - Controlled node for iCN operation - Redundant managing node for controller redundancy -
Ring redundancy - 2x hub - Multi ASend - PRC function 2 RJ45
X20 redundancy systems
X20 compact link selector, coated, 2x RJ45, order bus base, power supply module and terminal block separately.
Summary of Contents for X20 System