4.3.14.10.12.3 Current transformer rating phase A/B/C/N
Name:
I_RatioA
I_RatioB
I_RatioC
I_RatioN
Data type
Value
Information
UINT
10 to x
Current transformer rating
In the modules AP311, 21 and 31, the rated current is multiplied by the rated transformation ratio. In the module
AP3161, the maximum primary current of the transformer is configured directly.
The permissible values differ from module to module (resolution 0.1):
Module
Rating
X20AP3111
Transformer ratio: 10 to 32,500 (default: 25000)
X20AP3121
Transformer ratio: 10 to 650 (default: 500)
X20AP3131
Transformer ratio: 10 to 130 (default: 100)
X20AP3161
Measurement range: 50 to 650 (default: 500)
Information:
The maximum resulting current must not exceed the value of 65000 mA.
4.3.14.10.12.4 Update request ADC Cfg register
Name:
CfgUpdate
The registers in the group CfgReg are only updated after the CfgUpdate register is changed. Setting 0xFFFF only
causes this register to be reset without updating the CfgReg register.
Data type
Value
Information
UINT
0 to 65,535
Update request
4.3.14.10.12.5 Update request ADC Cs0, Cs1 and Cs3 register
Name:
Cs0Update
Cs1Update
Cs3Update
The registers in the group CsxReg are only updated after the CsxUpdate register is changed. Setting 0xFFFF only
causes this register to be reset without updating the CsxReg register.
Data type
Value
Information
UINT
0 to 65,535
Update request
Name:
Cs1UpdateFB
Cs3UpdateFB
The ADC configuration registers are only transferred to the feedback buffer after transfer to the ADC is complete.
Data type
Value
Information
UINT
0 to 65,535