4.11.11.9.4 SSI encoder - Configuration registers
4.11.11.9.4.1 SSI position values
Name:
Encoder01
The SSI encoder value is displayed as a 32-bit position value. The SSI position value is generated synchronously
with the X2X cycle.
Data type
Value
Filter
UDINT
0 to 4,294,967,295
SSI position
4.11.11.9.4.2 Input state of the digital input 1
Name:
DigitalInput01
This register displays the input state of the digital input.
Data type
Value
USINT
See bit structure.
Bit structure:
Bit
Name
Value
Information
3
DigitalInput01
0 or 1
Input state - Digital input 1
4.11.11.9.4.3 Status of encoder supply
Name:
PowerSupply01
This register shows the status of the integrated encoder supply. A faulty encoder power supply is displayed as
a warning.
Data type
Value
USINT
See bit structure.
Bit structure:
Bit
Name
Value
Information
0
24 VDC encoder power supply OK
0
PowerSupply01
1
24 VDC encoder power supply faulty
1 - 7
Reserved
-
4.11.11.9.5 Minimum cycle time
The minimum cycle time defines how far the bus cycle can be reduced without communication errors occurring.
It should be noted that very fast cycles decrease the idle time available for handling monitoring, diagnostics and
acyclic commands.
Minimum cycle time
128 μs
4.11.11.9.6 Maximum cycle time
The maximum cycle time defines how far the bus cycle can be increased without internal counter overflows causing
module malfunctions.
Minimum cycle time
16 ms
4.11.11.9.7 Minimum I/O update time
The minimum I/O update time defines how far the bus cycle can be reduced while still allowing an I/O update to
take place in each cycle.
Minimum I/O update time
128 μs