X20 system modules • Counter modules • X20DC2395
X20 system User's Manual 3.10
805
4.11.14.12.4.3 Set mask of the digital channels
Name:
CfO_OutSetMask
The settings in this register only affect the values written to registers 4.11.14.12.4.5 "DigitalOutput02 and 04".
•
0 allows manual setting of digital outputs using registers DigitalOutput02 and 04
•
1 prevents manual setting of digital outputs using registers DigitalOutput02 and 04
When "1" is used, the "output event function" can be used to set the outputs.
Data type
Value
USINT
See bit structure.
Bit structure:
Bit
Description
Value
Information
0
Reserved
-
0
Writing 1 to the DigitalOutput02 register sets the output
1
DigitalOutput02
1
Writing 1 from the DigitalOutput02 register does not set the out-
put
2
Reserved
-
0
Writing 1 to the DigitalOutput04 register sets the output
3
DigitalOutput04
1
Writing 1 from the DigitalOutput04 register does not set the out-
put
4 - 7
Reserved
-
4.11.14.12.4.4 Input states of the channels
Name:
see "Name in the AS I/O configuration"
This register reads the input status of a physical channel. The polarity settings are accounted for in the value (bit
2 in 4.11.14.12.4.1 "CfO_CFGchannel[x]" register).
The bits in this register are shown in the AS I/O mapping table under different names based on the function used
in order to improve readability.
Data type
Value
USINT
See bit structure.
Bit structure:
Bit
Physical input channel
Value
Name in the AS I/O configuration
0
Channel 1
0 or 1
DigitalInput01
1
Channel 2
0 or 1
DigitalInput02
StatusDigitalOutput02
2
Channel 3
0 or 1
DigitalInput03
3
Channel 4
0 or 1
DigitalInput04
StatusDigitalOutput04
ReferenceEnableSwitch01
ComparatorActualValue01
4 - 7
Reserved
-
Summary of Contents for X20 System