Technical data • Complete system
Chapter 2
Technical data
Panel PC 2100 swing arm user's manual V1.12
29
2.2.2 Humidity
The following table lists the minimum and maximum relative humidity values (non-condensing) for the individual
components that are relevant for the humidity limitations of a complete system. The lowest and highest common
values are always used when establishing these limits.
Display type
Model number
Operation
Storage
Transport
15.0" single-touch
5AP92D.1505-0x
8 to 90%
8 to 90%
8 to 90%
19.0" single-touch
5AP92D.1906-0x
5 to 90%
5 to 90%
5 to 90%
18.5" multi-touch
5AP93D.185B-0x
5 to 90%
5 to 90%
5 to 90%
18.5" multi-touch with operating
elements
5AP99D.185B-0x
5 to 90%
5 to 90%
5 to 90%
21.5" multi-touch
5AP93D.215C-0x
10 to 90%
10 to 90%
10 to 90%
21.5" multi-touch with operating
elements
5AP99D.215C-0x
10 to 90%
10 to 90%
10 to 90%
21.5" multi-touch with operating
elements
5AP99D.215I-0x
10 to 90%
10 to 90%
10 to 90%
24.0" multi-touch
5AP93D.240C-0x
5 to 90%
5 to 90%
5 to 90%
24.0" multi-touch with operating
elements
5AP99D.240C-0x
5 to 90%
5 to 90%
5 to 90%
Table 15: Display units - Humidity
All specifications apply to non-condensing operation/storage/transport.
Component
Model number
Operation
Storage
Transport
System units
5PPC2100.BYxx-001
5 to 90%
5 to 95%
5 to 95%
5CFAST.xxxx-00
Max. 85% at 85°C
Max. 85% at 85°C
Max. 85% at 85°C
CFast cards
5CFAST.xxxx-10
10 to 95%
10 to 95%
10 to 95%
5ACCIF01.FPCC-000
5 to 90%
5 to 95%
5 to 95%
5ACCIF01.FPCS-000
5 to 90%
5 to 95%
5 to 95%
5ACCIF01.FPLK-000
5 to 90%
5 to 95%
5 to 95%
5ACCIF01.FPLS-000
5 to 90%
5 to 95%
5 to 95%
5ACCIF01.FPLS-001
5 to 90%
5 to 95%
5 to 95%
5ACCIF01.FPSC-000
5 to 90%
5 to 95%
5 to 95%
5ACCIF01.FPSC-001
5 to 90%
5 to 95%
5 to 95%
Interface options
5ACCIF01.ICAN-000
5 to 90%
5 to 95%
5 to 95%
Table 16: System units, IF options, CFast cards - Humidity
The specifications listed correspond to the relative humidity (non-condensing) at an ambient temperature of 30°C.
More detailed information about specific temperature-dependent humidity values can be found in the technical data
for the individual components.
2.2.3 Vibration
The following table provides an overview of the maximum vibration specifications of the complete system. The use
of individual components may result in limitations.
Panel PC
Operation
1)
Storage
1)2)
Transport
1)2)
Continuous
Periodic
With CFast card
2 to 9 Hz:
1.75 mm amplitude
9 to 200 Hz: 0.5 g
2 to 9 Hz:
3.5 mm amplitude
9 to 200 Hz: 1 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
Table 17: Vibration
1)
Testing is performed in accordance with EN 60068-2-6.
2)
This value applies to a device in its original packaging.
2.2.4 Shock
The following table provides an overview of the maximum shock specifications of the complete system. The use
of individual components may result in limitations.
Panel PC
Operation
1)
Storage
1)2)
Transport
1)2)
With CFast card
15 g, 11 ms
30 g, 6 ms
30 g, 6 ms
Table 18: Shock
1)
Testing is performed in accordance with EN 60068-2-27.
2)
This value applies to a device in its original packaging.
2.2.5 Protection
The Panel PC 2100 swing arm device is rated IP65 in accordance with EN 60529 on all sides under the following
conditions: