Commissioning • Installation
136
Panel PC 2100 swing arm user's manual V1.12
1.5 Replacing a system unit
1. Disconnect the power supply to the Panel PC (disconnect the power cable). Isolate the system from all
potential sources of electrical power!
2. Discharge any electrostatic charge on the ground connection.
3. Remove the Panel PC interface cover, see
"Removing the interface cover" on page 134
.
4. Disconnect all connected cables.
5. Disconnect the Panel PC from the swing arm system by following the steps provided under item 3 in section
"Panel PC 2100 - Installation" on page 131
in reverse order.
6. Place the Panel PC on a clean, flat surface.
7. Remove the 4 Torx screws (T10) and heat sink.
Figure 52: Removing the Torx screws and heat sink
8. Remove the Torx screws (T10) indicated in the following image.
Figure 53: Removing the Torx screws