Technical data • General motor data
22
8JSA user's manual V1.00
10 General motor data
General information
Cooling type A
C-UR-US listed
Yes
Electrical properties
Mains input voltage on servo drive
3x 400 VAC ... 3x 480 VAC ±10%
Connection type
Motor connection
Encoder connection
speedtec circular connector from Intercontec
Size 1
Size 1
Thermal properties
Insulation class per EN 60034-1
F
Methods of cooling per EN 60034-6 (IC code)
Self-cooling, free circulation surface cooling (IC4A0A0)
Thermal motor protection per EN 60034-11
Maximum winding temperature 140°C
(limited by the thermal motor protection in the B&R drive system to 110°C with
EnDat feedback and 130°C with resolver feedback)
Mechanical properties
Vibration severity per EN 60034-14
Vibration severity stage A
1)
Roller bearing, dynamic load rating and nominal service life
Based on DIN ISO 281
Shaft end per DIN 748
Form E
Oil seal per DIN 3760
Form A
Key and keyway per DIN 6885-1
Form A keys, form N1 keyway
Shaft balancing per ISO 1940/1, G6.3
Shaft and fitment key convention
Mounting flange
IEC 72-1
Radial runout, concentricity and axial runout of mounting flange per DIN 42955 Tolerance N
Coating
Description
Color
Polyester powder coating
Mansfield 053-2006 polyester
Similar to RAL 9005 flat
Operating conditions
Rating class, operating mode per EN 60034-1
S1 - Continuous operation
2)
Ambient temperature during operation
5°C to 40°C
3)
Relative humidity during operation
5 to 95%, non-condensing
Maximum ambient temperature during operation
40°C
3)
Reduction of the nominal current and stall current at temperatures above 40°C 5% per 5°C
Maximum installation elevation
1000 m above sea level
4)
Reduction of rated and stall current at installation elevations
Starting at 1000 m above sea level
5% per 1000 m
EN 60034-5 protection (IP code)
With oil seal option
IP54
IP65
Type of construction and mounting arrangement per EN 60034-7 (IM code)
Horizontal (IM3001)
Vertical, motor hangs on the machine (IM3011)
5)
Vertical, motor stands on the machine (IM3031)
Storage and transport conditions
Storage temperature
-20 to 60°C
Relative humidity during storage
Max. 90%, non-condensing
Transport temperature
-20 to 60°C
Relative humidity during transport
Max. 90%, non-condensing
1)
Valid for all motors with a shaft height greater than 56 mm.
2)
The boundary conditions in section
"Power dissipation" on page 25
must be taken into account.
3)
Continuous operation of the servo motors at an ambient temperature of 40°C to max. 45°C is possible, but this results in premature aging.
4)
Requirements that go beyond this must be arranged with B&R.
5)
With the IM3011 type of construction and installation (vertical, motor hangs on the machine) there is a risk that production fluids or oils will penetrate the
motor on the flange side. Motors or motor-gearbox combinations that should be used in this type of installation must therefore have at least IP65 protection
on the flange side.