Software • B&R Automation Device Interface (ADI) driver - Control Center
Section 4
Soft
w
are
385
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
Change turn-off time for UPS
The
Shutdown time
can be specified in seconds under
Windows UPS service
. This is the
length of time that the UPS waits before switching off the power supply. When a critical alarm
occurs (e.g. at low battery level), the Windows UPS service will send a shutdown command with
the turn off delay time to the UPS and will shut down the system.
Activate UPS messages
Under "B&R UPS driver", activate the checkbox "UPS status messages". Any changes to the
UPS status will then trigger a message from the B&R UPS driver.
If the checkbox
Display UPS status with UPS monitor
is also activated, a new message is not
displayed for every change, but only a general message and request for you to start the B&R
UPS monitor. As long as the UPS monitor is active, no new messages are displayed.
Information:
Administer rights are required in order to display this dialog box.
Information:
This time is evaluated by the Windows UPS Service, but can not be set in the UPS
system settings of the energy options. This value should only be changed if the
system requires longer than the default setting of 180 seconds to shut down.
Caution!
The time entered must be longer than the time required to shut down the operating
system.
Information:
Shutting down the system is only reported by the Windows UPS Service. The UPS
Service also sends other messages if they are activated in the UPS system settings
energy options. These messages are only displayed when the Windows Alerter and
Windows Messenger
1)
are active and the PC is logged on to a network. Additionally,
some conditions of the B&R APC620 UPS are not detected by the Windows UPS
Service, and are therefore do not trigger messages (e.g. when there are no battery
settings on the UPS). The Windows Services can be found in the Control Panel
under Administrative Tools - Services.
1) The Windows Alerter is supported starting with B&R Windows Embedded Version 2.10 or higher.
Summary of Contents for Automation PC 620
Page 2: ...2 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 4: ...4 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 6: ...6 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 568: ...568 Appendix A Glossary Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...