5.6 Four Automation Panel 900 units via onboard SDL
An Automation Panel 900 is connected to the integrated SDL interface (onboard) via an SDL cable. Up to three
other Automation Panels of the same type are connected to this Automation Panel and operated via SDL. All four
panels show the same content (Display Clone).
USB is supported up to a maximum distance (SDL segment 1 + SDL segment 2) of 30 m on the first two panels
(front and back side). From a distance of 30 m and longer, USB is only available for the first panel (front and back
side). USB devices can only be connected directly to the Automation Panel (without a hub).
Automation PC 810
SDL Segment 1
Max. 40 m
Link: 5DLSDL.1000-01
No USB
possible
Link: 5DLSDL.1000-01
USB OK
Link: 5DLSDL.1000-01
Link: 5DLSDL.1000-00
SDL Segment 2
Max. 40 m
SD
L
Se
gm
en
t 3
M
ax
. 4
0
m
SDL Segment 4
Max. 40 m
No USB
possible
USB
possible
SDVO-B
Internal device number on the APC
Independent of segment length
Depends on segment length
Not supported
Monitor / Panel
Connection
Figure 88: Four Automation Panel 900 units via onboard SDL (sample photo)
5.6.1 Basic system requirements
The following table shows the possible combinations of APC810 system unit and CPU board to implement the
configuration shown in the figure above. If a combination results in a limitation of the maximum resolution, this is
also indicated (e.g. when connecting a non-B&R Automation Panel 900 device).
with system unit
CPU board
5PC810.SX01-00
5PC810.SX02-00
5PC810.SX03-00
5PC810.SX05-00
Limitation
Resolution
5PC800.BM45-00
✓
✓
✓
✓
Max. UXGA
5PC800.BM45-01
✓
✓
✓
✓
Max. UXGA
Table 146: Possible combinations of system unit and CPU board
5.6.2 Link modules
Information:
A corresponding link module must be selected for every device used.
Model number
Description
Note
5DLSDL.1000-00
Automation Panel Link SDL receiver
Connection for SDL in, transfer of display data, touch screen, USB 1.1, matrix keys, and service data, 24
VDC (screw clamp 0TB103.9 or cage clamp 0TB103.91 sold separately).
For Automation Panel 900
5DLSDL.1000-01
Automation Panel Link SDL transceiver
Connections for SDL in, transfer of display data, touch screen, USB 1.1, matrix keys, and service data,
24 VDC (screw clamp 0TB103.9 or cage clamp 0TB103.91 sold separately).
For Automation Panel 900
Table 147: Link modules
5.6.3 Cables
Select an Automation Panel 900 cable from the following table.
Model number
Description
Length
5CASDL.0018-00
SDL cable, 1.8 m
1.8 m ±30 mm
5CASDL.0050-00
SDL cable, 5 m
5 m ±30 mm
5CASDL.0100-00
SDL cable, 10 m
10 m ±50 mm
5CASDL.0150-00
SDL cable, 15 m
15 m ±100 mm
5CASDL.0200-00
SDL cable, 20 m
20 m ±100 mm
5CASDL.0250-00
SDL cable, 25 m
25 m ±100 mm
Table 148: Cables for SDL configurations