Commissioning • Configuration of a SATA RAID array
Chapter 3
Commissioning
Automation PC 810 with GM45 CPU board user's manual V1.28
205
7.5 Rebuild mirrored set
RAID Configuration Utility - Silicon Image Inc. Copyright (C) 2006
Create RAID set
Delete RAID set Rebuild help
Resolve Conflicts
Low Level Format
0 PM
1 SM
0 ST96023AS
Select Menu
1
ESC Previous Menu
Enter Select
Ctrl-E Exit
* First HDD
ST96023AS 55GB
ST96023AS 55GB
* Set0 SiI Mirrored Set <PM> 55GB
Current
ST96023AS rebuild
Rebuild Mirrored set
online rebuild
offline rebuild
Figure 103: RAID Configuration Utility - Rebuild mirrored set
The "Rebuild mirrored set" menu can be used to restart a rebuild procedure in a RAID 1 set if an error occurs, after
first interrupting the rebuild procedure or when exchanging a hard disk.
If "onlinerebuild" is selected, then the rebuild is executed during operation after the system is booted. E.g. an
event pop-up is displayed by the installed SATA RAID configuration program:
S A T A R a i d d e t e c t e d a n e w
e v e n t
and the rebuild is started. The entire rebuild lasts approximately 50 minutes.
If "offlinerebuild" is selected, then a rebuild is performed immediately before starting the operating system (duration
depends on the respective memory size).
7.6 Resolve Conflicts
RAID Configuration Utility - Silicon Image Inc. Copyright (C) 2006
Create RAID set
Delete RAID set Help for resolving
Rebuild Mirrored set conflicts
Low Level Format
0 PM
1 SM
0 ST96023AS
Select Menu
1
ESC Previous Menu
Enter Select
Ctrl-E Exit
* First HDD
ST96023AS 55GB
ST96023AS 55GB
* Set0 SiI Mirrored Set <PM> 55GB
Current
ST96023AS Current
Resolve Conflicts
Figure 104: RAID Configuration Utility - Resolve conflicts
Conflicts in a RAID set can be resolved using the "Resolve conflicts" menu. This function is only available if the
status of the hard disk is "conflict".