PLACING OF PLATES FOR MAGNETICAL LIMIT SWITCHES

1.

Plate  L.S. in closing (Fig 6). Position the gate in complete
closing, place the magnet at the centre of the buttonhole
and sold it to the rack in central direction of the group “Limit
switch”.

2.

Plate L.S. in opening (Fig 7). Position the gate  in complete
opening,  place  the  magnet  at  the  centre  of  the  buttonhole
and sold it to the rack in central direction of the group “Limit
switch”.

PLACING OF PLATES FOR MECHANICAL LIMIT SWITCHES

1.

Plate L.S. in closing (Fig 9). Position the gate in complete
closing and sold the stirrups at the centre of  the group limit
switches. Therefore fix the slide in the appropriate plate
hole. (Fig 8).

2.

Plate L.S. in opening (Fig 9). Position the gate in complete
opening and sold the stirrups at the centre of  the group
limit switches. Therefore fix the slide in the appropriate
plate hole. (Fig 8). (Fig 8).

USAGE

It  is  forbidden  to  use  the  motor  for  different  purposes.  The  control
panel installed, that must have the electronic power regulation, allows
to select the functioning:

AUTOMATIC

: an impulse of command executes the opening and

the closing of the gate;

SEMI-AUTOMATIC

: an impulse of command execute the opening

or the closing of the gate.

In case of energy lack, act on the manual unlocking device and move
the  gate  manually.  Please  remember  that  we  are  in  the  presence  of
an automatic device feed  with electric energy so therefore used  with
all the precaution. In particular is exhorted to:

don’t touch the device with wet hands and or with wet or naked
foots;

Cut the energy before opening the command box or then piston;

don’t pull the feeding cable to disconnect the plug;

Allow to move the gate only when completely visible;

Stay out of the action range of the gate, if this is in movement: wait
until it’s completely stopped;

don’t let the children or the animal play in the proximity of the gate;

don’t let the children use the remote controls or the other
commands of the gate;

do a periodical maintenance;

In case of damages, cut the energy and move the gate manually
only if possible and safe. Don’t do any intervention but call
specialized stuff.

MAINTENANCE

The  motor  gear  MC4  is  provided  by  a  permanent  lubrication  with
grease so it doesn’t need of any maintenance: nevertheless his good
functioning  depends  also  to  the  state  of  the  gate,  therefore  we  will
describe some operations in order to have always an efficient gate.
Warning:  none  apart  the  maintainer,  that  must  be  a  specialized
technicians,  could  operate  the  gate  in  automatic  during  the
maintenance. It is suggested therefore to cut electric energy, avoiding
also electric shocks. If, otherwise, the energy must be present for any
possible need, is recommended to check or deactivate any command
device (remote controls, pushbuttons, etc).

ORDINARY  MAINTENANCE:

Each  one  of  the  following  operations

must  be  done  when  we  realize  the  need  and  in  any  case  every  6
months.

1)

Mechanic maintenance

Clean from debris the rail ant the relatives wheels;

Check the good functioning of the motor and the relative plate;

do an unlocking maneuver in order to be sure that the
mechanism will always be efficient.

2)

Electric maintenance

Check the good state of the safety devices;;

Check the efficiency of the electronic power regulation

Check the efficiency of the ground system. Test the differential
switch one time per month, pushing the test button on the
switch.

USAGE OF THE MANUAL RELEASE

In case it necessary to manually move the gate, cause a black
out or damages to the automation, it is necessary to use the
manual release system, as follows:

Open the cover using the personalized key and pull down the lever.

To lock again the system, put the lever in the original position and lock
the cover with the key.

Summary of Contents for MC10

Page 1: ...ding 230 Vca 50 Hz 10 Protection Grade IP44 Power 650W 0 9HP Working temperature 20 C 70 C Max weight of the gate 2000 Kg Capacitor 25 uF 400 V Speed 9 m min Clutch Double disk Maximum torque 5 daN Th...

Page 2: ...tested and settled according to the current laws and also a suitable external independent disconnecting switch which has to be adjusted on the current charge Throughout the installation procedure the...

Page 3: ...the upper part of the buttonhole This position allows to adjust the rack when the motor in the time will lower 2 Unlock the motor 3 Move manually the leaf in an opening position 4 Place the rack over...

Page 4: ...wait until it s completely stopped don t let the children or the animal play in the proximity of the gate don t let the children use the remote controls or the other commands of the gate do a periodic...

Page 5: ...e 39 0422 857377 Fax 39 0422 857367 email proget proget beb com Ponte di Piave 15 02 2005 Officer In Charge GINO BASSI The description and the electrical plan of this instructions guide are not bindin...

Page 6: ...been observed the following rules EN 13241 1 Doors and industrial commercial and residential gates Product rule Products which are not resistant to the fire or without smoking control EN 12453 Porte...

Page 7: ...Location Address of the installation LIST OF INSTALLED COMPONENTS The technical features and the performances of the listed components below are described in the related manuals of installation and or...

Page 8: ...gulations Maintenance Repairing Modifies Notes Trimmer Dipswitch Jumper Date Technician s signature Client s signature Description of the intervention Tick the square according to the intervention don...

Reviews: