Accessories
Mobile Panel 7200 User's manual V 1.01
67
7.3.1.5 Safety characteristics
Criteria
Characteristic value
Maximum performance level (PL) per EN ISO
13849-1:2015
MTTF
d
(mean time to dangerous failure)
>100 years (high)
DC
avg
(diagnostic coverage)
60% < DC < 90% (low)
PFH
D
(probability of dangerous failure per hour)
<6.4 x 10
-8
Mission time
20 years
Table 20: 4MPCBX.0000-00 - Safety characteristics
7.3.1.6 Dimensions
26
.2
172.5
ø 4.5
ø 9
150.2
158.7
74
.7
81
.7
7.3.1.7 Drilling template 4MPCBX.0000-00
10
0
26
.2
161
172.5
ø 4 / M4
7.3.1.8 Content of delivery
Quantity
Component
1
Connection box 4MPCBX.0000-00
2
Screw plugs M16x1.5 (screwed on)
1
Screw plugs M20x1.5 (screwed on)
1
Protective cover in place (design similar to 5CAMPP.0001-10)
A box cable (5CAMPB.0xxx-10) is necessary to establish the electrical connection between the control cabinet
and connection box.