Appendix B
Mobile Panel 7200 User's manual V 1.01
75
Appendix B Enabling control device
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Information:
In order to ensure the specified safety characteristics, the enabling electronics must be taken out of
operation after 20 years at the latest.
Properties
Enabling control device with one enable switch
Output type
Electromechanical switching contact
Switchable nominal voltage (Ue)
24 VDC, SELV
1)
(voltage tolerance 19.2 VDC to 30 VDC per EN 61131-2)
Switchable nominal current (Ie)
500 mA (max.)
Short circuit and overload protection
No
Reverse polarity protection
No
Utilization category
DC13
Operating cycles (B
10d
)
Switch position 2
1,000,000
Switch position 3
5,000,000
Actuating force
From switch position 1 to 2
Typically 3 N
From switch position 2 to 3
Typically 17 N
Electrical isolation
500 VAC to rest for 1 minute
Output testing
-
Changing grip function
-
Output synchronization
-
Specifications for EN ISO 13849-1:2015
Enable
Category
4
Performance level
e
Proof test interval
20 years
Specifications for EN 64508
1)
EN 60950 requirements must be observed.