Appendix A • Mounting compatibility
Appendix A
Power Panel 500 user's manual V1.40
297
5.2.4 12.1" devices
Cutout tolerance values for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 are ±0,5 mm.
The cutout tolerance values from the AP1000 are +0 mm/-0.5 mm.
362 x 284
8.5
8.5
8.5 PP100/200/300/400
10 AP900, PPC700, PP500, AP1000
1.5
Outer contour of device
Cutout for PP100/200/300/400 device
PP100/200/300/400
AP900/PPC700
8.5 PP100/200/300/400
10 AP900, PPC700, PP500, AP1000
Cutout for AP900/PPC700/PP500/AP1000 device
1.5
342 x 267
345 x 267
PP500
AP1000
Figure 175: Mounting compatibility - 12.1" device - Horizontal1
12.1" Automation Panel 1000, Automation Panel 900, Panel PC 700 and Power Panel 500 devices are not 100%
mounting compatible with Power Panel 100/200/300/400 devices in Horizontal1 format. The Power Panel 300/400
and Power Panel 100/200 devices require a cut that is 1.5 mm wider (left and right).
The larger cutout can be used for all devices under certain conditions:
•
When mounting, make sure that the AP1000, AP900, PPC700 and PP500 devices are mounted as close
to the center of the cutout as possible.