5.2.5 15" devices
Cutout tolerance values for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 are ±0,5 mm.
The cutout tolerance values from the AP1000 are +0 mm/-0.5 mm.
435 x 330
8.5 PP500, AP1000
9 PP100/200/300/400, AP900, PPC700, PPC800
9 PP100/200/300/400, AP900, PPC700, PPC800
8.5 PP500, AP1000
10
10
PP100/200/300/400
AP900/PPC700
PP100/200/300/400
AP900
PP500
PP500
0.5
0.5
PPC800
AP1000
AP1000
Cutout for PP100/200/300/400/AP900/PPC700/PPC800 device
Cutout for - PP500/AP1000 device
Outer contour of device
415 x 312
415 x 313
Figure 176: Mounting compatibility - 15" device - Horizontal1
15" Automation Panel 1000 and Power Panel 500 devices are not 100% mounting compatible with Power Panel
100/200/300/400, Automation Panel 900, Panel PC 700 and Panel PC 800 devices in the Vertical1 format. Au-
The larger cutout can be used for all devices under certain conditions:
•
When mounting, make sure that the PP100/200, PP300/400, AP900, PPC700 and PPC800 devices are
placed and mounted as close to the center of the cutout as possible. Failure to do so can prevent the
retaining clips from holding firmly, which means that a firm seal is no longer guaranteed with the gasket
(IP65).
435 x 430
8.5 PP500
9 PP100/200/300/400/AP900/PPC700
10
9 PP100/200/300/400/AP900/PPC700
8.5 PP500
10
Outer contour of device
Cutout for PP100/200/300/400/AP900/PPC700 device
415 x 412
PP100/200/300/400
AP900
Cutout for PP500 device
415 x 413
PP500
0.5
0.5
Figure 177: Mounting compatibility - 15" device - Vertical1
15" Power Panel 500 devices are not 100% mounting compatible with Power Panel 100/200/300/400, Automation
Panel 900 and Panel PC 700 devices in the Vertical1 format. The Power Panel 500 devices require a cutout that
is 0.5 mm higher (top and bottom edge).
The larger cutout can be used for all devices under certain conditions:
•
When mounting, make sure that the PP100/200, PP300/400, AP900 and PPC700 devices are mounted as
close to the center of the cutout as possible. Failure to do so can prevent the retaining clips from holding