5.2 Replacement of modules
Replace PCB52, Digi module
- Remove screws and remove bottom plate
- Remove all cables and place Master Link
Gateway on a ESD proof surface
- Remove PCB52, Digi module, carefully (be
careful not to damage the 2 sockets)
After replacement it is important to:
- Initialise the serial number of the product into
the new module
- Transfer the customer’s backup data into the
new module
10x
TX10
Master Link Gateway in service position
WWW.BEOWORLD.ORG