Fault flow chart 3.3
Fault symptom:
No Master Link
communication in ML
Gateway
Navigation from user
interface ok
Possible causes:
Software fault.
Defective PCB01,
Mainboard.
Defective PCB52, Digi
module.
Update software for
ML Gatway.
Confirm Master
Link communication
OK?
Replace PCB01
Mainboard.
Confirm Master
Link communication
OK?
Replace defective
PCB52, Digi module
Done!
Check cables for ML
connection
OK?
Replace defective
ML cable
No
Yes