Fault flow chart 3.5
Fault symptom:
No RS232 communication in
ML Gateway
Navigation from user interface
ok.
Possible causes:
Software fault
Defective RS232 cable
Defective PCB01, Mainboard
Defective PCB52, Digi module
Update software for
ML Gatway.
Confirm RS232
communication
OK?
Replace PCB01,
Mainboard.
Confirm RS232
communication
OK?
Replace defective
PCB52, Digi module
Done!
Check cables for
RS232 connection
OK?
Replace defective
RS232 cable
No
Yes
WWW.BEOWORLD.ORG
Summary of Contents for 1798
Page 10: ...2 4 W W W B E O W O R L D O R G...
Page 16: ...3 6 W W W B E O W O R L D O R G...
Page 26: ...4 10 W W W B E O W O R L D O R G...
Page 30: ...5 4 W W W B E O W O R L D O R G...
Page 32: ...6 2 W W W B E O W O R L D O R G...
Page 34: ...7 2 W W W B E O W O R L D O R G...
Page 37: ...W W W B E O W O R L D O R G...