4.2 Adjustments
Ajdustments in general
Information
Generally there are few adjustments to be made in ML Gateway, when modules
has been replaced.
To maintain or service ML Gateway there is no need for a special ServiceTool as
known from other Bang & Olufsen products. All types of service or adjustments
are executed from a web-based user interface.
Survey of adjustments
The follwing adjustments/settings are available in the web-based user interface:
- Network Settings.
- Setting up the date and time in the product.
- Setting up the text size (to fit screen resolution of the web interface).
- Change password (login password to ML Gateway).
- Master Link Gateway Protocol settings.
- Serialising the serial number into the product (PCB52, Digi module).
- Backup/restore the customer’s data to a new PCB52, Digi module.
Additional information
! The web interface is organised into a series of screens which can be selected by
means of the navigation bars.
Try to avoid using the browser’s back and forward navigation buttons, as you may
lose the information you are entering.
Also, note that changing to another screen does not save the modifications you
have made. There are ‘Apply’ or ‘Save’ buttons next to most controls and data
fields.
! When a configuration is uploaded to ML Gateway, e.g. when PCB52, Digi module
is replaced, the uploaded project will not be activated automatically (it will only
replace the current EDIT version).
It is required to TEST and then SAVE the newly uploaded configuration in order to
activate it. For this procedure please refer to the ‘Programming’ section in ML
Gateway.
! When it is required to initialise the serial number in to ML Gateway (only relevant
when PCB52, Digi module is replaced) a command line interface (CLI) must be
used. For this purpose it is recommended to use
Telnet*
which usually is
implemented in Windows XP, Windows Vista and Mac OS.
Accessing Command Promt (PC users) or Terminal (Mac users):
Windows XP:
Start -> Programs -> Accessories -> Command Prompt
Windows Vista:
Start -> All Programs -> Accessories -> Command Prompt
Mac OS:
Go -> Utilities -> Terminal
To activate
Telnet
type:
telnet 192.168.1.10
* In some cases
Telnet
is not activated per default on Vista installations. To activate
Telnet
click:
Start -> Control Panel -> Programs and Features -> Turn
Windows features on or off
-> select
Telnet Client
-> click
OK
(in some cases
the Windows Vista installation DVD is required to install
Telnet
).
WWW.BEOWORLD.ORG
Summary of Contents for 1798
Page 10: ...2 4 W W W B E O W O R L D O R G...
Page 16: ...3 6 W W W B E O W O R L D O R G...
Page 26: ...4 10 W W W B E O W O R L D O R G...
Page 30: ...5 4 W W W B E O W O R L D O R G...
Page 32: ...6 2 W W W B E O W O R L D O R G...
Page 34: ...7 2 W W W B E O W O R L D O R G...
Page 37: ...W W W B E O W O R L D O R G...