Troubleshooting 2.3
Troubleshooting
MLGW not working after software update
Detecting if MLGW is running
The following are signs that the MLGW application is not running:
- The front panel indicator does not turn green after approximately 1 minute of
being powered up.
- Briefly pressing the setup button produces no visible feedback on the front panel
indicator.
- The unit automatically reboots every minute or so (check for system boot
indication on the front panel, or critical error indication).
If the application seems to be running, but you cannot connect either via web or
via telnet (command line interface), first check that the network is working as
usual; then try resetting the network settings through the front panel.
For further details regarding network connectivity, please refer to the Network
settings in the section ‘Adjustment’.
Restarting MLGW on factory-installed software
If a software update causes MLGW to fail (for example due to power failure during
flash update), the unit can be restarted using the original factory-installed software.
To do this, switch MLGW off, and while pressing the setup button, switch it back
on. Release the setup button only after 5 seconds. This will start the system using
the original factory software, but will not fix or replace the ‘broken’ software. You
need to log into the system and perform a software upgrade to ‘repair’ the
software.
If you suspect that the failure is inherent to the latest software installed (and not a
failure during the flash process), then you can manually download an earlier
software version from BeoWise to you computer, and perform a software update
from that file.
Erasing entire configuration before application start
If the application fails to start even if restarting on factory-installed software, there
is a method for erasing the entire configuration from MLGW before the
application starts up. This can be useful in case of a corrupt configuration, or a
configuration which causes the older factory-installed software to fail.
The entire configuration is erased if the setup button is pressed when the
application starts (front panel indicator goes from RED to GREEN) and is released
within 1 second. So the normal procedure for this is to power up MLGW with the
setup button pressed, and release it as soon as the front panel indicator goes from
RED to GREEN (approximately 40 seconds after power-up).
WWW.BEOWORLD.ORG
Summary of Contents for 1798
Page 10: ...2 4 W W W B E O W O R L D O R G...
Page 16: ...3 6 W W W B E O W O R L D O R G...
Page 26: ...4 10 W W W B E O W O R L D O R G...
Page 30: ...5 4 W W W B E O W O R L D O R G...
Page 32: ...6 2 W W W B E O W O R L D O R G...
Page 34: ...7 2 W W W B E O W O R L D O R G...
Page 37: ...W W W B E O W O R L D O R G...