LED indications 12
LED indications
The LED in the lover edge of the connection panel gives feedback about the system status of the BeoLink Gateway.
Green
Red
Description
Solid
-
Normal operation
Flashing quickly
Flashing quickly
Critical error
-
Solid
H8/FEP/FPGA update
Flashing slowly
-
Software update/System boot
-
Flashing slowly
Master Link synchronization
Functions - by Setup button
The
Setup
button placed next to the LED provides a number of functions as
described in the following.
- Press and hold the
Setup
button and the system will cycle through the functions. The LED indicates the function number by flashing red a number
of times: function no 1 = one flash, function no 2 = two flashes, etc.
- Count the number of red flashes while holding the
Setup
button, and when the desired number is reached let go the button.
- The LED indicator starts to flash red.
- To confirm the function execution the setup button should be pressed again within 3 seconds.
No.
Function
Description
1
System event
Executing macros with EVENT
2
Reset password to default
‘Password’ to factory default
3
Fixed IP-address
Enables the default static IP-address (192.168.1.10)
4
Factory default
Erases configuration and settings
5
-
-
6
Dynamic IP-address
Enable DHCP (dynamic IP-address)