Banner AG4 Series Safety Laser Scanner
Settings:
Activated
Deactivated
Default value: Activated
6.2.4
Applicable field pair selection at Scanner start
The Applicable field pair selection at Scanner start parameter indicates which field pair may be active when the Scanner starts.
Settings
The applicable field pairs in a matrix are selected:
x
: Field pair allowed with start
Empty field: Field pair forbidden with start
Default values: Field pairs 1, 2, 3 and 4 allowed
6.2.5
Permitted field pair switchover
The Permitted field pair switchover parameter indicates the switchover from field pair to field pair that is permitted and in which sequence. The
Scanner stops the machine when a forbidden switchover sequence is requested.
Settings
The permitted field pair switchover in a matrix are selected:
x
: Field pair switchover permitted
Empty field: Field pair switchover forbidden
Default values: No field pair switchover allowed
6.3
Field pair
6.3.1
PF description
The Description parameter names the PF.
Settings
Max. 20 characters
Default values: PF1 to PF4
6.3.2
WF description
The Description parameter names the WF.
Settings
Max. 20 characters
Default values: WF 1 to WF 4
Product Manual
P/N 144924 05/2009
55