• Connect pin "Earth" of the TCNM-ACBB1 connection box to a good earth ground
• For direct connections, connect the cable shield to the locking ring nut of the connector
3.6.2 Inputs
There are two opto-isolated polarity insensitive inputs available on the M12 17-pin connector of the reader: Input 1 (External
Trigger) and Input 2, a generic input. See
on page 29 for more details.
The electrical features of both inputs are:
INPUT
| V AB | Minimum
| V
AB
| Maximum
I
IN
Maximum
Open
0 V
2 V
0 mA
Closed
4.5 V
30 V
10 mA
The relative pins on the M12 17-pin connector are:
Pin
Function
1
Power Supply input v
2
Power Supply input voltage -
3
Input 2 B (polarity insensitive)
5
External Trigger B (polarity insensitive)
6
External Trigger A (polarity insensitive)
13
Input 2 A (polarity insensitive)
3.6.3 Outputs
Three general purpose non opto-isolated but short circuit protected outputs are available on the M12 17-pin connector.
The pinout is the following:
Pin
Function
9
Configurable digital output 1
8
Configurable digital output 2
16
Configurable digital output 3
2
Power Supply Input Voltage -
The electrical features of the three outputs are the following:
Outputs
3 NPN/PNP/Push-Pull software selectable, reverse polarity and short circuit protected outputs available (2 Opto-isolated outputs instead if using
on page 33 for specifications)
Maximum Current: 100 mA maximum
Output Saturation Voltage (in PNP or NPN mode): < 3 V at 100 mA
Maximum load device voltage drop (in NPN mode): 30 V
The output signals are fully programmable being determined by the configured Activation/Deactivation events, Deactivation
Timeout or a combination of the two. For further details refer to the Help On Line page for the Output Setup step in Barcode
Manager.
CAUTION: For NPN output connections, the external interface voltage (Vext) must not exceed the ABR
power supply source voltage (Vdc) otherwise correct output functioning cannot be guaranteed.
ABR 7000 Series Barcode Reader
18