• Discard After Read—After the last code in the output buffer is read by the EtherNet/IP server manager (host), it is
deleted from the output buffer. In this way it will not be re-read by the same host (or any host) in case of a re-
connection.
When there is more than one code in the output buffer, the EtherNet/IP protocol requires that each code read by the host
be deleted and replaced by the next code in the output buffer.
8.2.3
ABR
Series EDS File Installation in Studio 5000 Logix Designer
Software
Use the EDS Hardware Installation Tool to register the Electronic Data Sheet (EDS) file.
Use the follow the steps, as well as
ABR Series Manual Installation in Studio 5000 Logix Designer Software
quickly and easily establish an implicit Class 1 connection between the ABR and a Rockwell Studio 5000 Logix Designer
family PLC. Screenshots are from an example configuration with a ControlLogix 1756-L71 with a 1756-ENBT/A Ethernet
module, using Studio 5000 Logix Designer version 30.
1. Download
Banner_ABR_1_1_08312018.eds
from
.
2. On the Tools menu, click EDS Hardware Installation Tool.
The Rockwell Automation's EDS Wizard dialog displays.
Figure 79. Tools—EDS Hardware Installation Tool
3. Click Next.
4. Select Register an EDS file(s).
Figure 80. Rockwell Automation's EDS Wizard—Options
ABR 7000 Series Barcode Reader
68
www.bannerengineering.com - Tel: + 1 888 373 6767