Banner AG4 Series Safety Laser Scanner
66
P/N 144924 05/2009
Product Manual
12.
Carefully put the two housing parts back
together. The two retaining bolts must slide
into the rubber sleeves provided for this.
Carefully tighten the Allen screws on the
housing rear by alternating between them.
1 Retaining
bolts
2 Rubber
sleeves
Remove any fingerprints on the front
screen.
8.4
Calibrating the front screen
Requirements:
The new front screen is correctly mounted.
Front screen is clean and scratch-free.
Ambient temperature: 20° C – 25° C
CAUTION . . . ENSURE FRONT SCREEN IS CLEAN
Faulty calibration may be caused by a dirty or scratched front screen.
Only calibrate front screens that are clean and free of scratches and marring.
Connect interface X1 with the control system.
Connect interface X2 with the PC.
Calibrate the front screen using the software; see AG4soft Software Instruction Manual.
8.5 Disposal
Dispose of Scanner that can no longer be used according to all applicable specifications and regulations.
8.6 Repairs
Do not attempt any repairs to the Scanner, other than replacement of the screens. It contains no other field-replaceable components. Return it
to the factory for warranty repair or replacement. Contact Banner Factory Application Engineering at the address or the numbers listed on the
back page. They will attempt to troubleshoot the system from your description of the problem. If they conclude that a component is defective,
they will issue a return merchandise authorization
(RMA) number for your paperwork, and give you the proper shipping address.
Pack the Scanner carefully. Damage which occurs in return shipping is not covered by warranty.